Types Of Installation; Wall Mounting - Siemens SIMATIC NET SCALANCE MUM856-1 Operating Instructions Manual

Industrial remote communication - remote networks
Hide thumbs Also See for SIMATIC NET SCALANCE MUM856-1:
Table of Contents

Advertisement

Assembly and disassembly

4.1 Types of installation

4.1
Types of installation
Note
• The device is only approved for operation in closed rooms. Note the following
environmental conditions.
• Antennas, in particular directional antennas, must be mounted in keeping with their
characteristics (refer to the technical specifications of the antenna --> Radiation pattern
diagrams).
For the device the following types of installation are permitted:

• Wall mounting

• Mounting on a DIN rail
The device can be mounted on a DIN rail with
– a DIN rail mounting adapter
– a bracket support and the DIN rail mounting adapter for space-saving installation (90°
4.2
Wall mounting
Note
Depending on the mounting surface, use suitable fittings.
Note
The wall mounting must be capable of supporting at least four times the weight of the
device.
To mount the device on a wall, follow the steps below:
1. Prepare the drill holes for wall mounting. For the precise dimensions, refer to the section
"Dimension drawing".
2. Insert the SIM card, see section "SIM card (Page 49)".
3. Secure the device to the wall with four screws. The screws are not supplied with the device.
4. Connect the power supply, refer to the section "Power supply (Page 44)".
5. Fit the antennas, refer to the section "Antennas (Page 47)".
32
installation)
Operating Instructions, 08/2021, C79000-G8976-C628-02
SCALANCE MUM856-1

Advertisement

Table of Contents
loading

Table of Contents