Physical/remote access
• If possible, operate the devices only within a protected network area. Attackers cannot
access internal data from the outside when the internal and the external network are
separate from each other.
• Limit physical access to the device exclusively to trusted personnel.
The memory card or the PLUG (C-PLUG, KEY-PLUG, CLP) contains sensitive data such as
certificates and keys that can be read out and modified. An attacker with control of the
device's removable media could extract critical information such as certificates, keys, etc.
or reprogram the media.
• Lock unused physical ports on the device. Unused ports can be used to gain forbidden
access to the plant.
• We highly recommend that you keep the protection from brute force attacks (BFA)
activated to prevent third parties from gaining access to the device. For more information,
see the configuration manuals, section "Brute Force Prevention".
• If possible, use the VPN functionality to encrypt and authenticate communication for
communication via non-secure networks.
• When you establish a secure connection to a server (for example for an upgrade), make
sure that strong encryption methods and protocols are configured for the server.
• Terminate the management connections (e.g. HTTPS, SSH) properly.
• Make sure that the device has been powered down completely before you decommission
it. For more information, refer to "Decommissioning (Page 3)".
• We recommend formatting a PLUG that is not being used.
Hardware/Software
• Use VLANs whenever possible as protection against denial-of-service (DoS) attacks and
unauthorized access.
• Restrict access to the device by setting firewall rules or rules in an access control list (ACL).
• Selected services are enabled by default in the firmware. It is recommended to enable only
the services that are absolutely necessary for your installation.
For more information on available services, see "List of available services (Page 9)".
• Use the latest web browser version compatible with the product to ensure you are using
the most secure encryption methods available. Also, the latest web browser versions of
Mozilla Firefox, Google Chrome, and Microsoft Edge have 1/n-1 record splitting enabled,
which reduces the risk of attacks such as SSL/TLS Protocol Initialization Vector
Implementation Information Disclosure Vulnerability (for example, BEAST).
• Ensure that the latest firmware version is installed, including all security-related patches.
You can find the latest information on security patches for Siemens products at the
Industrial Security (https://www.siemens.com/industrialsecurity) or ProductCERT Security
Advisories (https://www.siemens.com/cert/en/cert-security-advisories.htm) website.
For updates on Siemens product security advisories, subscribe to the RSS feed on the
ProductCERT Security Advisories website or follow @ProductCert on Twitter.