Accurate Specifications
B. AC Voltage
Range
Resolution
2V
1mV
20V
10mV
±(0.8%+5)
200V
100mV
750V
1V
±(1.0%+4)
Remark:
• Input impedance: 10MΩ.
• Frequency response: 40Hz ~ 400Hz.
• Displays effective value of sine wave
(mean value response).
C. DC Current
Range
Resolution
200mA
0.1mA
±(0.8%+5)
10A
10mA
±(1.2%+4)
Remark:
• At 10A Range:
For continuous measurement
and interval time between 2 measurement
greater than 15 minutes.
D. Resistance
Range
Resolution
200Ω
0.1Ω
2kΩ
1Ω
20kΩ
10Ω
±(0.8%+5)
200kΩ
100Ω
2MΩ
1kΩ
20MΩ
10kΩ
±(1.5%+5)
E. Diode
Range
Resolution
1mV
Remark:
• Open circuit voltage approximate 2.7V
• The silicon PN junction normal voltage
is about 500 mV to 800 mV
F. Continuity Testing
Range
Resolution
1Ω
Remark:
• Open circuit voltage approximate 2.7V.
• The buzzer does not sound when the resistance
value is >50Ω. The circuit is disconnected.
• The buzzer sounds continuously when
the resistance value is 30Ω. The circuit
is in good condition.
Accuracy
Overload protection
1000 VDC or 750
VAC continuous
Accuracy
Overload protection
CE:Fuse 315mA, 250V
fast type, ø5x20mm
CE:Fuse 10A, 250V
fast type, ø5x20mm
10 seconds
Accuracy
Overload protection
600Vp
Overload protection
600Vp
Overload protection
600Vp
G. Dwell Testing
Range
Resolution
4CYL
6CYL
0.1º
8CYL
Remark:
Input Amplitude: More than or equal to 10 V in
direct impulse; more than or equal to 0.5 ms
in width.
H. Tach (Rotation Speed) Testing
Range
Resolution
4CYL
6CYL
10 RPM
8CYL
Remark:
• Input Amplitude: More than or equal to 10 V
in direct impulse; more than or equal
to 0.5 ms in width.
• Maximum Tach: 10000 RPM,
Tach = Displayed Reading x 10.

Maintenance

This section provides basic maintenance
information including battery and fuse replacement
instruction.
WARNING
Do not attempt to repair or service your
multimeter unless you are qualified to do so and
have the relevant calibration, performance test,
and service information. To avoid electrical shock
or damage to the multimeter, do not get water
inside the case.
A. General Service
• Periodically wipe the case with a damp cloth and
mild detergent. Do not use abrasives or solvents.
• To clean the terminals with cotton bar with
detergent, as dirt or moisture in the terminals
can affect readings.
• Turn the Meter off when it is not in use and take
out the battery when not using for a long time.
• Do not store the Meter in a place of humidity,
high temperature, explosive, inflammable
and strong magnetic field.
B. Replacing
the Fuses
(see
figure 21)
14
Accuracy
Overload protection
±(3%+5)
600 VP
Accuracy
Overload protection
±(3%+5)
600 VP
Holster
Screw
figure 21