Technical Data - Dometic TCX Series Operating Manual

Thermoelectric cooler
Table of Contents

Advertisement

TCX14, TCX21, TCX35
Fault
Your cooling device
does not cool satisfac-
torily and the fan impel-
ler at the outside does
not rotate.
Your cooling device
does not cool satisfac-
torily and the fan impel-
ler at the outside
rotates.
10

Technical data

Ref. no.:
Input voltage:
Power input:
Interior temperature range
(7 to 1 LEDs)
– Cooling:
Interior temperature range
(7 to 1 LEDs)
– Heating:
Category:
Energy efficiency class:
EN
Possible cause
The ventilator motor is
defective.
The ventilator motor
for the inner ventilator
is defective.
The thermo-electric
element is defective.
The integrated power
unit is defective.
TCX14
9600014289
8.5 W
(AC, ECO mode)
1 °C to 16 °C
(max. 27 °C below ambient temperature)
Suggestion
The repair can be executed only by an
authorized customer service.
TCX21
9600014290
12/24 Vg
220 – 240 Vw
46 W (12 Vg)
50 W (24 Vg)
64 W (230 Vw)
8.8 W
(AC, ECO mode)
3 °C to 16 °C
48 °C to 65 °C
Pantry
A++
Technical data
TCX35
15