Changing codes
"Holiday program heating circuit 2"
Function
"Holiday period HC2":
"Start" (Day 1)
"Holiday period HC2":
"End" (Last day)
"Holiday operating level
HC2"
"Holiday program heating circuit 3"
Function
"Holiday period HC3":
"Start" (Day 1)
"Holiday period HC3":
"End" (Last day)
"Holiday operating level
HC3"
"Heating circuit 1"
Function
"Room temperature
comfort setpoint"
"Room temperature re-
duced setpoint"
"Room temperature frost
protection setpoint"
"Heating curve slope"
(see page 81)
"Heating curve displace-
ment" (see page 81)
"Summer/winter heating
limit" (see page 159)
"24-hour heating limit"
(see page 159)
(cont.)
Code
Operat-
ing level
652
"E"
653
"E"
658
"E"
Code
Operat-
ing level
662
"E"
663
"E"
668
"E"
Code
Operat-
ing level
710
"E"
712
"E"
714
"E"
720
"F1"
721
"F1"
730
"F1"
732
"F2"
Setting options
Delivered
condition
01/01 to 31/12
- -.- -
01/01 to 31/12
- -.- -
■ "Frost protec-
"Frost pro-
tion"
tection"
■ "Reduced"
Setting options
Delivered
condition
01/01 to 31/12
- -.- -
01/01 to 31/12
- -.- -
■ "Frost protec-
"Frost pro-
tion"
tection"
■ "Reduced"
Setting options
Delivered
condition
6 to 35 °C
20.0
6 to 35 °C
14.0
4 to 35 °C
4.0
0.10 to 4.00
1.40
- 4.5 to 4.5 °C
0.0
- - -/8 to 30 °C
18
- - -/- 10 to 10 °C
0
Codes