1.

INTRODUCTION

In this section you can find a general description and safety instructions related to the
installation and usage of the fitting.
SafeLED heliport inset light is an omnidirectional, LED-based light fixture. It is a robust
construction designed for harsh weather environments with encapsulated electronics.
The housing is IP67 protected. The protrusion above ground is only 9 mm for minimal
risk of external mechanical impact. It can be mounted in shallow bases with a total
depth of only 100 mm. The SafeLED heliport inset light comes with a cable in order to
make the installation easy and safe.
1.1

SAFETY INSTRUCTIONS

Make sure you read this section and are familiar with safety precautions before any
work is started.
1.1.1

Product Safety

Airfield lighting fixtures in a constant current circuits are connected in a circuit via
isolating transformers with currents between 2.0 – 6.6A in the primary circuits. The
primary voltages, depending on the circuitry, are usually several kilovolts and
therefore lethal. Although the open circuit voltages of the isolating transformers are
much lower, the peak voltage while opening the secondary circuit under current is
also hazardous. So it is vitally important to follow all the safety regulations with
adequate circumspection.
In the design of this equipment all the practical safety aspects have been taken into
account. It is also important to strictly follow existing international or national
regulations, the instructions established by civil aviation authority or airport operator
and the following instructions.
1.1.2

Electrical Maintenance

Valid safety regulations must always be followed. Never carry out any maintenance or
maintenance measures before the current is confirmed as safely disconnected. Use
extreme caution when disconnecting or connecting high voltage primary connectors.
WARNING! PRIOR TO THE COMMENCEMENT OF WORK ALL ELECTRICAL
SERVICES MUST BE ISOLATED FROM THE SUPPLY AND CONNECTED TO
EARTH. FULL DETAILS OF THE WORK INVOLVED MUST BE GIVEN TO THE
AUTHORISED PERSON RESPONSIBLE FOR THE ELECTRICAL ENGINEERING
SERVICES AT THE AIRPORT WITH REGARD TO THE DURATION OF THE WORK
AND SO ON. IT IS RECOMMENDED THAT PRIOR TO STARTING ANY CUTTING
WORK, THE NATURE AND LOCATION OF SERVICES SUCH AS CABLE DUCTS
AND THE LIKE SHOULD BE IDENTIFIED. ANY INSTALLATION OR MAINTENANCE
WORK SHOULD ONLY BE CARRIED OUT BY TRAINED AND EXPERIENCED
PERSONNEL. ALSO, WHEN WORKING ON CIRCUITS USING AIRFIELD SMART
POWER SYSTEM (ASP) THE SCM MUST BE TUNED OFF.
1.1.3

Mechanical Maintenance

When maintaining mechanical components, it is important to follow the instructions for
electrical maintenance.