Replacing A Led Assembly With Holder - Safegate Group SL-HF-I Manual

Table of Contents

Advertisement

Airfield Lighting
Manual
Ref: SL-HF-I; SL-HT-I
Water tightness check
It is recommended to verify that the fitting is
water tight:
(a) Remove the water tightness test valve cap.
(b) Fill up the fitting with compressed air (test
pressure = 140 kPa or 20 psi).
(c) Put the fitting in water, wait 3 minutes and
check if air bubbles leave the fitting.
If that is the case, the fitting is not water
tight. Disassemble the fitting once again to
check/clean all contact surfaces and check
gaskets. Replace if necessary.
3.2.2

Replacing a LED Assembly with Holder

Remove
(a) Disassemble the fitting (see § 3.2.1
Disassembling/ Assembling the Fitting).
(b) Using a 5 mm Allen key, unscrew and
remove the fixing screws of the prism
holder.
(c) Remove the LED assembly.
Replace
(a) Connect cable from the converter to the
LED-board
(b) Place a new LED assembly on the fitting.
(c) Fasten the LED holder assembly using the 6
M6x20 mm fixing screws with a torque
limiting spanner with a torque of 6,5 N m,
(see fig 10 – Fixing screw order).
(d) Assemble the fitting (see § 3.2.1
Disassembling/ Assembling the Fitting).
FIGURE 9 – FIXING SCREW ORDER
Page 11 of 16
Safegate Group
Date: September 2014
Version: 1.3
FIGURE 8 – LED

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-ht-i

Table of Contents