Workshop Maintenance; Disassembling/ Assembling The Fitting - Safegate Group SL-HF-I Manual

Table of Contents

Advertisement

Airfield Lighting
Manual
Ref: SL-HF-I; SL-HT-I
The light is designed for outdoor operation, however storing the light outside without
using it is a risk for damage to light components. For a longer storage time (more than
a week), it is recommended to store the light indoors in a dry and dust free
environment and at room temperature. Proper storage ensures trouble free
replacement procedures. It is strongly recommended not to store any electrical
equipment outside.
3.2

WORKSHOP MAINTENANCE

It is important to always make sure that the fitting is depressurized before disassembly
for maintenance work.
Before you start, make sure you have read and understand §1.1 Safety Instructions.
Note: Only the most common maintenance procedures are instructed in following
paragraphs. Construction of the luminaire allows a full disassembling and replacement
of all the parts if required.
The workshop maintenance refers to following actions:

1. Disassembling/ assembling the fitting

2. Replacing a LED assembly with holder
3.
Replacing the prism and its gasket
3.2.1
Disassembling/ Assembling the Fitting
Disassemble
(a) Untighten the two housing screws using a
5 mm Allen key.
(b) Lift up the bottom cover and disconnect the
LED-board cable.
(c) Remove the O-ring gasket from the bottom
cover.
Assemble
Carefully clean all contact surfaces of the fitting
and the cover.
(a) Place a new O-ring gasket in the track in the
bottom cover.
Note: The O-ring gasket must be changed
each time the fitting is opened.
(b) Connect the LED-board to the converter.
(c) Put the bottom cover back in place and
tighten the two screws using a torque
limiting spanner with a torque of 8 N m
(equivalent to 0.8 kg m or 8 g cm).
Page 10 of 16
Safegate Group
Date: September 2014
Version: 1.3
FIGURE 7 – DISASSEMBLY

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-ht-i

Table of Contents