Advertisement

Quick Links

Airfield Lighting
Manual
8" SafeLED Omnidirectional Inset Light
(SL-HF-I; SL-HT-I)
 Final Approach and Take Off area
 Touchdown and Lift Off area
 Aiming Point

Advertisement

Table of Contents
loading

Summary of Contents for Safegate Group SL-HF-I

  • Page 1 Airfield Lighting Manual 8” SafeLED Omnidirectional Inset Light (SL-HF-I; SL-HT-I)  Final Approach and Take Off area  Touchdown and Lift Off area  Aiming Point...
  • Page 2 Note: This page is blank for convenient double-sided printing.
  • Page 3: Table Of Contents

    3.2.2 Replacing a LED Assembly with Holder ..........11 3.2.3 Replacing the Prism and its Gasket ............12 SUPPORT ........................13 SAFEGATE GROUP WEBSITE ..............13 RE-CYCLING ....................13 4.2.1 Local Authority Re-cycling ..............13 4.2.2 Safegate Group Re-cycling ..............13 SPARE PARTS ....................
  • Page 4 Note: It is very important to read this document before any work is started. Copyright © Copyright 2012 by Safegate Group. All rights reserved. This item and the information contained herein are the property of Safegate Group. No part of this...
  • Page 5: Introduction

    Safegate Group Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 INTRODUCTION In this section you can find a general description and safety instructions related to the installation and usage of the fitting. SafeLED heliport inset light is an omnidirectional, LED-based light fixture. It is a robust construction designed for harsh weather environments with encapsulated electronics.
  • Page 6: Description Of The Fitting

    Safegate Group Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 DESCRIPTION OF THE FITTING The SafeLED Heliport inset light is an 8” omnidirectional low projection LED light fixture provided with optional green or white LED. The light fixture is designed for parallel VAC circuits, 230V 50Hz.
  • Page 7: Installation

    Safegate Group Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 INSTALLATION In this section you can find a description of the different steps for successful installation of the fitting. Before you start, make sure you have read and understand §1.1 Safety Instructions.
  • Page 8: Installing/ Removing The Fitting

    Safegate Group Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 INSTALLING/ REMOVING THE FITTING Install (a) Open the box and verify that the characteristics of the fitting correspond to your design requirements (type, colour etc.). (b) Control the label on the fitting for product information.
  • Page 9: Electrical Connections

    Safegate Group Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 ELECTRICAL CONNECTIONS The fittings for the heliport are power supplied with 230 Vac, 50Hz. The design of the electrical circuits can include junction boxes, allowing connection in parallel of the fittings.
  • Page 10: Cable Grounding

    Safegate Group Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 FIGURE 6 – TERMINALS AND HEAD SHRINKABLE SLEEVES 2.2.1 Cable Grounding For safety reasons the fitting shall be grounded with the protective earth (PE) ground wire (green/yellow wire). It is recommended to use a separate fuse and a residual current device on the circuit.
  • Page 11: Maintenance

    Safegate Group Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 MAINTENANCE In this section you can find a description of the different steps for the maintenance of the fitting. Before you start, make sure you have read and understand §1.1 Safety Instructions.
  • Page 12: Workshop Maintenance

    Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 The light is designed for outdoor operation, however storing the light outside without using it is a risk for damage to light components. For a longer storage time (more than a week), it is recommended to store the light indoors in a dry and dust free environment and at room temperature.
  • Page 13: Replacing A Led Assembly With Holder

    Safegate Group Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 Water tightness check It is recommended to verify that the fitting is water tight: (a) Remove the water tightness test valve cap. (b) Fill up the fitting with compressed air (test pressure = 140 kPa or 20 psi).
  • Page 14: Replacing The Prism And Its Gasket

    Safegate Group Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 3.2.3 Replacing the Prism and its Gasket Remove (a) Disassemble the fitting (see § 3.2.1 Disassembling/ Assembling the Fitting). (b) Using a 5 mm Allen key, untighten and remove the 6 fixing screws of the LED assembly.
  • Page 15: Support

    4.2.1 Local Authority Re-cycling The disposal of Safegate Group products is to be made at an applicable collection point for the recycling of electrical and electronic equipment. The correct disposal of equipment prevents any potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling.
  • Page 16: Spare Parts

     Main Unit Serial Number. Safegate Group will continue to monitor and update according for any future requirements for EU directives as and when EU member states implement new regulations and or amendments. It is our aim to maintain our compliance plan and assist our customers.
  • Page 17 Safegate Group Airfield Lighting Manual Date: September 2014 Ref: SL-HF-I; SL-HT-I Version: 1.3 Note: This page is blank for convenient double-sided printing. Page 15 of 16...
  • Page 18 Malmö, Sweden. Safegate Group has more than 70 partners around the globe in order to be close to its customers. Earlier members of Safegate Group include Thorn AFL and Idman, who both have over 40 years of experience in airfield lighting solutions for airports and heliports.

This manual is also suitable for:

Sl-ht-i

Table of Contents