INTEgRaTEd FuNCTIONS

leak detection
• The display shows "EC" when the outdoor unit detects a leak in the refrigerant circuit.
Memory function for the horizontal air louvre
• The unit remembers the motion and angle of the horizontal air intake. If the maximum angle is exceeded, it returns to the basic setting.
TuRbO
• The turbo function takes the unit to the set temperature in the shortest possible time. If you are in COOl mode and press TuRbO, the unit
will blow cold air with a high fan speed. If you are in HEaT mode, it will blow hot.

guaRaNTEEd TEMPERaTuRE RaNgE

Function (MOdE)
Room temperature
Outdoor temperature
IMPORTaNT!
The unit functions optimally at these temperatures. using the unit in other temperature conditions can affect performance/operational reliability.
* as this is an air conditioner optimised for cooling, the unit is limited to heating with an outdoor temperature of down to 5°C. The unit then
switches off and restarts at 8°C. This applies to HEaT mode. The code "P3" is shown on the indoor unit's display.

EMERgENCy OPERaTION MOdE

If, for any reason, the unit's remote control does not work, you can temporarily run
the unit in "emergency operation mode". The button is on the right side of the indoor
unit (see figure).
Press the button once to start the unit in emergency operation auTO.
Press the button once again to start the unit in emergency operation COOl.
Press the button once again to stop the unit.
AIR
Cooling (COOl)
17°C ~ 32°C
-15°C ~ 50°C
Heating (HEaT)
17°C ~ 30°C
5°C ~ 30°C*
24
dehumidifying (dRy)
10°C ~ 32°C
0°C ~ 50°C