Yaesu VX-8GR/GE Operating Manual page 129

144/430 mhz dual band fm transceiver with gps
Table of Contents

Advertisement

S
M
I
ET
ODE
TEM
50: MEMORY SKIP
Selects the Memory Scan channel-selection mode.
51: MEMORY WRITE
Determines the method of selecting channels for Memory Storage.
52: MESSAGE LIST
Programming a Member List for the Message feature.
53: MESSAGE REGISTER
Selects your Personal ID for the Message feature.
54: MESSAGE SELECT
Programming a Message for the Message feature.
55: MIC GAIN
Adjusts the microphone gain level.
56: MONI/T-CALL
Selects the MONI/T.CALL key (just below the PTT switch) function.
57: MUTE
Adjusts the receiver audio output level when the MUTE function was activated.
58: OFF TIMER
Set the OFF Timer time.
59: ON TIMER
Set the ON Timer time.
60: OPENING MESSAGE
Selects the Opening Message that appears when the radio is powered on.
61: PAGER ANS-BACK
Enables/Disables the Answer Back function of the Enhanced CTCSS Paging & Code Squelch.
62: PAGER CODE-RX
Sets the Receiver Pager Code for the Enhanced CTCSS Paging & Code Squelch.
63: PAGER CODE-TX
Sets the Transmitting Pager Code for the Enhanced CTCSS Paging & Code Squelch.
64: PASSWORD
Programming and activating the Password feature.
65: PR FREQUENCY
Program the CTCSS Tone Frequency for the User Programmed Reverse CTCSS Decoder.
66: PRI REVERT
Enables/Disables the Priority Revert feature.
67: PRI TIME
Selects the time between the Priority (Dual Watch) channel checks, when the feature is
active.
68: PTT DELAY
Selects the time delay before the carrier is transmitted, when the PTT switch is pressed.
69: RPT ARS
Enables/Disables the Automatic Repeater Shift function.
70: RPT SHIFT
Sets the Repeater Shift Direction.
71: RPT SHIFT FREQ
Sets the magnitude of the Repeater Shift.
72: RX MODE
Sets the receiving mode.
73: SAVE RX
Selects the Receive-mode Battery Saver interval ("sleep" ratio).
74: SAVE TX
Enables/Disables the Transmitter Battery Saver.
75: SCAN LAMP
Enables/Disables the Scan Lamp (while scanner is paused).
76: SCAN RE-START
Selects the Scan Re-start Delay time.
77: SCAN RESUME
Selects the Scan Resume mode.
78: SENSOR DISPLAY
Selects the sensor information when the transceiver is operating in the "Mono" band mode
with large characters.
79: SENSOR INFO
Indicates the Information of the internal sensors.
80: SET MODE CSR
Selects the Set Mode Cursor.
81: SET MODE FORMAT
Selects the display format of the Set Mode operation.
82: SMART SEARCH
Selects the Smart Search Sweep mode.
83: S-METER SYMBOL
Selects the S- & TX PO meter Symbol.
84: SPEC-ANALYZER
Selects the Spectrum Analyzer sweep mode.
85: SQL LEVEL
Sets the Squelch threshold level.
86: SQL S-METER
Adjusts the Squelch threshold level to the S-meter level.
87: SQL SPLIT
Enables/disables split CTCSS/DCS coding.
88: SQL TYPE
Selects the Tone Encoder and/or Decoder mode.
89: STEP FREQUENCY
Setting of the DIAL frequency steps.
90: TIME SET
Sets the Clock time.
91: TONE FREQUENCY
Setting of the CTCSS Tone Frequency.
92: TONE-SRCH MUTE
Enables/Disables the receiver audio output while the Tone Search Scanner is activated.
93: TONE-SRCH SPEED
Selects the Tone Search Scanner speed.
94: TOT
Setting of the TOT time.
95: VFO MODE
Selects or disables the VFO band edge limiting for the current band.
96: VFO SKIP
Setting My Band.
97: VIBRATOR
Enables/Disables the Vibrator function.
98: VIBRATOR MODE
Selects the vibration mode of the Vibrator function.
Select the [ VOL ] key function.
99: VOLUME MODE
100: WX ALERT
Enables/Disables the Weather Alert Feature.
1: Depends on the transceiver version.
2: Depends on the operating band and transceiver version.
VX-8GR/GE O
PERATING
F
UNCTION
M
ANUAL
S
M
ET
ODE
A
V
VAILABLE
ALUES
( D
: U
B
EFALT
NDERLINED
OLD
OFF / SKIP / ONLY
NEXT / LOWER
--
--
--
LEVEL 1 ~ LEVEL 9 ( LEVEL 5 )
MONI / T-CALL
1
MUTE 30%, MUTE 50%,
MUTE 100%, or OFF
--
--
NORMAL / OFF / DC / MESSAGE
ON / OFF
--
--
--
300Hz ~ 3000Hz (1000Hz/step) ( 1600Hz )
ON / OFF
0.1sec ~ 0.9sec (0.1sec/step) or
1.0sec ~ 10.0sec (0.5sec/step) ( 5.0sec )
OFF / 20ms / 50ms / 100ms / 200ms
ON / OFF
SIMPLEX / -RPT / +RPT
0.000MHz ~ 150.000MHz (50 kHz/step)
AUTO / NFM / AM
0.2sec ~ 0.9sec (0.1sec/step),
1.0sec ~ 9.5sec (0.5sec/step), or
10.0sec ~ 60.0sec (5sec/step)
ON / OFF
ON / OFF
0.1sec ~ 0.9sec (0.1sec/step) or
1.0sec ~ 10.0sec (0.5sec/step) ( 2.0sec )
2.0sec ~ 10.0sec (0.5sec/step) /BUSY /
HOLD ( 5.0sec )
DC / TEMP / OFF
--
Nine patterns
LIST / ITEM
SINGLE / CONTINUOUS
Four patterns
1Time / CONTINUOUS / Full Time
LEVEL 0 ~ LEVEL 15 ( LEVEL 1 )
OFF / LEVEL 0 ~ LEVEL 9
OFF / ON
OFF / TONE / TONE SQL / DCS /
REV TONE / PR FREQ / PAGER / MESSAGE
AUTO / 5.0 / 6.25 / 8.33 / 10.0 / 12.5 / 15.0 /
20.0 / 25.0 / 50.0 / 100.0 kHz
--
50 standard CTCSS tones ( 100.0Hz )
ON / OFF
FAST (2.5 tone/sec) / SLOW (1.25 tone/sec)
OFF / 0.5min ~ 10.0min (0.5min/step)
( 3.0min )
ALL / BAND
--
OFF / BUSY / SIGNALING
MODE1 / MODE2 / MODE3
NORMAL / AUTO BACK
ON / OFF
)
2
127

Advertisement

Table of Contents
loading

Table of Contents