Panasonic AK-HC5000 Operating Instructions Manual page 60

Table of Contents

Advertisement

Item
[INITIAL GAMMA]
[KNEE]
Item
[KNEE]
[KNEE MASTER POINT] Sets the knee point position.
[KNEE R POINT]
[KNEE B POINT]
[KNEE MASTER
SLOPE]
[KNEE R SLOPE]
[KNEE B SLOPE]
[WHITE CLIP]
Item
[WHITE CLIP]
[MASTER WHITE CLIP LEVEL]
[R WHITE CLIP LEVEL]
[B WHITE CLIP LEVEL]
[HI-COLOR]
[HI-COLOR LEVEL]
[DRS]
Item
[DRS]
[EFFECT DEPTH]
[DETAIL SETTING]
Item
[DETAIL]
Chapter 4 Menu Operations — Menu list
Sets the gamma initial slope.
When [GAMMA MODE SELECT] is [HD]: [4.0]/[4.5]/[5.0]
When [GAMMA MODE SELECT] is [FILMLIKE1]/[FILMLIKE2]/[FILMLIKE3]: [4.5] (fixed)
When [GAMMA MODE SELECT] is [FILE REC]/[VIDEO REC]: [4.5] (fixed)
f Factory setting: [4.5]
Enables/disables the knee function.
[OFF], [ON]
f Factory setting: [ON]
[080.00%]...[110.00%] (0.25% step)
f Factory setting: [95.00%]
Adjusts the knee point of red to [KNEE MASTER POINT].
[−25.00]...[25.00%] (0.25% step)
f Factory setting: [0.00%]
Adjusts the knee point of blue to [KNEE MASTER POINT].
[−25.00]...[25.00%] (0.25% step)
f Factory setting: [0.00%]
Sets the knee slope.
[00]...[199]
f Factory setting: [130]
Adjusts the knee slope of red to [KNEE MASTER SLOPE].
[−99]...[+99]
f Factory setting: [0]
Adjusts the knee slope of blue to [KNEE MASTER SLOPE].
[−99]...[+99]
f Factory setting: [0]
Enables/disables the white clip function.
[OFF], [ON]
f Factory setting: [ON]
Sets the white clip level.
[80%]...[109%]
f Factory setting: [109%]
Adjusts red to [MASTER WHITE CLIP LEVEL].
[−15%]...[+15%]
f Factory setting: [0%]
Adjusts blue to [MASTER WHITE CLIP LEVEL].
[−15%]...[+15%]
f Factory setting: [0%]
Sets whether to improve the color reproduction in high-luminance areas.
[OFF], [ON]
f Factory setting: [OFF]
Sets the level of the mode that expands the color dynamic range.
[1]...[32]
f Factory setting: [32]
Enables/disables the dynamic range stretcher function. Set this to [ON] to automatically adjust the
contrast.
[OFF], [ON]
f Factory setting: [OFF]
Sets the compression level of the high-luminance areas of the dynamic range stretcher function. Set a
larger value to increase the compression level of the high-luminance areas.
[1]...[5]
f Factory setting: [5]
Enables/disables all detail functions.
[OFF], [ON]
f Factory setting: [ON]
– 60 –
Description of settings
Description of settings
Description of settings
Description of settings
Description of settings