Summary of Contents for Sharp Plasmacluster KC-30TX1
Page 1
This product is equipped with the generator with the indicated After reading, keep the manual in a convenient location capacity. for future reference. Plasmacluster is a registered trademark or a trademark of Sharp Corporation. This unit is not for commercial use.
Page 27
Contents Page FEATURES .................................. FAQs SAFETY PRECAUTIONS ........... PART NAMES ..............PREPARATION ..............Filter Installation ..............Equipment Installation Pour water in the Water Tank OPERATION ................ E-10 Clean Air & Humidify Mode Clean Air Mode Plasmacluster ion Shower Mode ..........
The effect of sterile filtration / purification varies depending on the environment of the room where the product is used for 60 minutes to purify air rapidly. and the usage. For details on Plasmacluster technology, please visit official site of Sharp Corporation in Japan.
FAQs The number in shows the page page on which the main description is provided. I cannot see steam. Is it really humidifying? Doesn't the product humidify the room too much? With this product, "vaporization system" that generates damp air by blowing the wind to the Humidifying filter is adopted instead of a system that generates vapor (steam) by boiling water, so you cannot see the vapor.
SAFETY PRECAUTIONS Be sure to follow the instructions below: To prevent harm to a person and damage to assets, the contents you obey are being explained. ■ The contents caused by the wrong use by ■ The kind of obeyed contents is being classifying as follows divided by the next symbol.
Page 31
Prevent leakage or injury, CAUTION to protect the property Plug and power cord: Be sure to hold the plug to pull out the Be sure to unplug the unit if not used for power cord. a long period of time. (Fire, electric shock and/or short circuit could (Insulation failure could cause fire from electric result)
PART NAMES Main unit, operation part and monitor Front Air outlet (front) Operation part Lights Control Button page Filter Reset Button/ Indicator Light (red) Main page unit ON/OFF Timer Button/ Indicator Light (yellowish green) page Plasmacluster ion ON/OFF Button / Indicator Light page (yellowish green) Monitor...
Page 33
Press any button indicated with start operation. Plasmacluster Ion Sign (blue) Lighting: “ON”, Not lighting: “OFF” Blinking: “Plasmacluster ion Shower in operation” POWER OFF Button 〜 page Fan Speed Button / page Indicator Light (yellowish green) Plasmacluster ion Shower Mode Button / Indicator Light (yellowish green) page Clean Air &...
PREPARATION Filter Installation Be sure to install filters before plugging the unit. Upper tabs (one each at right and left) Remove the back panel to take the found in the main unit. filters out. Back panel De-formaldehyde Deodorizing HEPA filter filter filter Take filters (3 types)
In case TV or radio broadcast signals become noisy or an atomic radio watch or Insert the plug into the outlet clock does not display the correct time, after preparation. move the unit away from the TV, radio or atomic radio timepieces. Installation Use the unit in a room at between approx.
Insert the plug into the outlet. OPERATION Clean Air & Humidify Mode The operation in this mode is generally recommended. (Humidity setting cannot be adjusted.) Fill up the Water Tank with tap water page Water tank after the plug is inserted into the outlet, set the fan speed to “AUTO”...
Plasmacluster ion Shower Mode When the air in a room suddenly becomes polluted brought home The full-power operation is carried out at slightly strong air volume for 60 minutes to purify air rapidly. The operation status automatically returns to the previous status in 60 minutes. from the laundry dried indoors Beep Humidify Indicator Light...
CONVENIENT FUNCTIONS Lights Control Press the Button when the monitor or Plasmacluster Ion Sign is too bright (In operation) Caution ON/OFF Timer If you set the timer, the product is automatically operated or stopped at the time you set. Press the Button to change settings as follows: Select the reservation time …...
When the dust monitor or odor monitor does not change from "Red" … adjust it to "LOW" does not change from "Green" … adjust it to "HIGH" Adjustment of Sensor Detection Sensitivity Press and (When the unit is OFF) hold down for 3 or more seconds (In 8 seconds)
WARNING Be sure to power OFF and unplug the unit prior CARE AND MAINTENANCE to care. Pull out the plug [Electric shock and/or injury could result] When “Clean Filter Indicator Light” turn on Indicates when to clean the Water Tank, Humidifying Filter, Humidifying Tray / Humidifying Tray Lid and Back Panel. Unplug operates for 24 hours Handle of...
Be sure to clean the unit to keep it clean for use. Once a month Water Tank with Tank cap Caution holding the carrying <<Every time the Water Tank is filled>> handle. Pour a small amount of water into tank with the tank the Water Tank and cap down.
WARNING Be sure to power OFF and unplug the unit prior CARE and MAINTENANCE to care. Pull out the plug (Continued) [Electric shock and/or injury could result] Main unit When heavily dirty Do not use the following: (Surfaces could be damaged or entry of the fluid inside (precision part) could cause failure) Thi nne r Unplug...
When an odor is generated from Deodorizing Filter / De-formaldehyde Filter / HEPA Filter the air outlet When an odor is persisting *Clean the Deodorizing Filter, De-formaldehyde Filter and HEPA Filter at the same time Never rinse the Filter with water. (The filter performance will be degraded) Never clean the other white surface.
WARNING Be sure to power OFF and unplug the unit prior CARE and MAINTENANCE to care. Pull out the plug (Continued) [Electric shock and/or injury could result] When they are heavily dirty or odor bad Unscrew the Water Tank Cap and wash the inner Soak the panel in diluted kitchen Water Tank and the Cap.
IMPORTANT INFORMATION Filter Performances HEPA filter * Deodorizing filter De-formaldehyde filter (dust mite feces and (odor) dead mites) (odor) (particles) (carbon monoxide from cigarettes, etc.) (odor from building materials including formaldehyde, pet odor, etc.) The black surface cloth is uneven in density, which will not affect filter performances. For effective use smoke, or grilled meat, the odor is attached to the filter and odor may be generated in a few weeks to a few months.
WARNING Be sure to power OFF and unplug the unit FILTER REPLACEMENT prior to replace. Pull out the plug [Electric shock and/or injury could result] Once every 5 years Humidifying filter Model: FZ-BB90ZK Sold in China FZ-3TX1MF Sold in Japan Humidifying filter life if: E-14...
Check the following table before calling TROUBLESHOOTING for service or contacting us. Refer Remedy Symptom E-10~11 Water is not reduced from the Water Tank Water is reduced more E-14 slowly than before E-14~15,18 Humidity does not rise. E-14~15,18 Clean the filter Odors or smoke is not removed.
Page 48
TROUBLESHOOTING (Continued) Refer Remedy Symptom The Dust Monitor or Odor E-13 Monitor does not change. one day. E-13 The Dust Monitor or Odor Monitor does not turn green. The Dust Monitor or Odor Monitor change the E-13 color frequently. The display on the front of E-12 the main unit is too bright.
Page 49
Refer Symptom Remedy The Float or Roller came off. Roller Float (Do not disassemble) Float projection Float direction. Sectional view You can set recovery. Want to automatically restart operation when electric power is restored from power failure. (When the unit is OFF) Beep (For 3 or more seconds simultaneously)
Page 76
相談窓口 夏普商貿(中国)有限公司 〒200001 上海市黄浦区延安東路550号海洋大廈27F-29F シャープPCI清浄機専用ライン : 400-018-2128 ※中国語対応のみ Contact address Sharp Electronics Sales (China) Co., Ltd. (SESC) 27-29F, Ocean Towers, No. 550 East Yan An Road, Huangpu District, Shanghai City, 200001, P. R. China Exclusive line for Sharp PCI Air Purifier: 400-018-2128 * Only Chinese guidance is available.