Sharp KC-F30J Operation Manual

Air purifier with humidifying function

Advertisement

KC-F30J
"Plasmacluster" and "Device of a cluster of
grapes" are trademarks of Sharp Corporation.
Free standing type
KC-F30J_EN.indd
1
R
AIR PURIFIER
with Humidifying Function
OPERATION MANUAL
*The number in this technology mark indicates
the approximate number of ions supplied into 1
3
cm
of air, which is measured around the center
of a room (with the "High-Density Plasmacluster
7000" applicable floor area), at a height of 1.2m
above the floor, at the MAX wind volume setting
in air purifying mode, and when a humidifier
& air purifier or an air purifier using the high-
density plasmacluster ion evolving device is
placed close to a wall. This product is equipped
with a device of corresponding capacity.
2018/05/24
13:24:41

Advertisement

Table of Contents
loading

Summary of Contents for Sharp KC-F30J

  • Page 1 Humidifying Function OPERATION MANUAL “Plasmacluster” and “Device of a cluster of grapes” are trademarks of Sharp Corporation. *The number in this technology mark indicates the approximate number of ions supplied into 1 of air, which is measured around the center of a room (with the “High-Density Plasmacluster...
  • Page 2 Before operating your new air purifier, please read the following The air purifier draws in room air through the air intake, circulates it through a Pre-Filter, a Deodorizing Filter and a HEPA Filter inside the unit, and then discharges it through the air outlet.
  • Page 3: Table Of Contents

    Sensor technology continuously monitors air quality and automatically adjusts operation based on air purity and humidity level. Thank you for purchasing this SHARP Air Purifier. Please read this manual carefully before using the air purifier. After reading, keep the manual in a convenient location for future reference.
  • Page 4: Important Safety Instructions

    Sharp authorized Service Center or a similarly qualified service provider. • Only a Sharp Authorized Service Center should service this air purifier. Contact the nearest Service Center for any problems, adjustments, or repairs. •...
  • Page 5 CAUTIONS CONCERNING OPERATION • Do not operate the unit without the filters and the Humidifying Tray properly installed. • Keep the unit away from water. • Do not wash and reuse the HEPA filter and Deodorizing filter. Doing so will not improve filter performance and can also cause electric shock or operating malfunctions.
  • Page 6: Part Names

    PART NAMES FRONT / BACK FRONT BACK BACK (Plug shape varies by country.) Operation Panel / Display (Ref.E-5) Humidifying Tray Handle (2 Locations) Float Main Unit HEPA Filter Air Outlet Deodorizing Fiter Filter Frame Sensor (internal) Humidifying Filter Back Panel (Pre-Filter) Float (in Filter Frame) Air lnlet Tray Handle...
  • Page 7 OPERATION PANEL / DISPLAY Display Dust Sign Indicates the air purify level 3 colors. Clean Green Orange Impure Humidify Light Humidity / Temperature monitor Green....Humidify ON Indicates the approximate humidity / temperature level in the room. Green....Unit needs water temperature 0 to 50ºC is displayed at 1ºC-intervals (Flashing) Off ......
  • Page 8: Preparation

    PREPARATION PREPARATION Always be sure to remove the Always be sure to remove the power plug from the wall outlet. power plug from the wall outlet. FILTER INSTALLATION FILTER INSTALLATION Humid The u Remove the Back Panel. Back Panel HEPA filter Deodorizing filter Remove the Filters from the plastic bag.
  • Page 9 REFILLING THE HUMIDIFYING TRAY Humidify air passed through by vaporizing water pumped up from Humidifying Tray. The unit can be used even without water in the Humidifying Tray. Humidifying Tray Pull out the CAUTION Clean the Humidifying Tray if it becomes dirty or there is a noticeable odor.
  • Page 10: Operation

    OPERATION Power ON / OFF • Select the desired fan speed by START STOP • Unless the power cord has been unplugged, the operation starts in the previous mode it was operated in. CLEAN ION SHOWER Releases high-density Plasmacluster ions and discharges strong air flow for 60 minutes. START NOTE •...
  • Page 11: Useful Function

    USEFUL FUNCTION LIGHT CONTROL You can set the front surface Indicators to OFF when the Indicator is too bright. Press Press more than 3 more than 3 seconds. seconds. Plasmacluster Ion ON/OFF When Plasmacluster Ion is ON, the Plasmacluster Ion Indicator Light is on. (blue) NOTE Press Press...
  • Page 12 USEFUL FUNCTION Off TIMER Select the length of time you want. The unit automatically stops once the selected time is reached. 1 hour 2 hours 4 hours 8 hours CANCELLATION NOTE • Pressing displays the remaining time. • To reset the operating time, press while the remaining time is being displayed.
  • Page 13 CARE AND MAINTENANCE CARE AND MAINTENANCE FILTER INDICATOR The filter Indicator Light will turn After performing on after approximately 720 hours. maintenance, reset (30 days × 24 hours =720 hours) the Filter Indicator. This is a reminder to perform the maintenance described below.
  • Page 14 CARE AND MAINTENANCE CARE AND MAINTENANCE from HUMIDIFYING FILTER / TRAY Odor occurrence may be suppressed when washing Humidifying Filter and Humidifying Tray with water carefully even if the Filter Indicator Light is not ON. Remove the Humidifying Filter from the Tray. Turn down Remove Pull up...
  • Page 15: Filter Frame

    Always be sure to remove the power plug Always be sure to remove the power plug from the wall outlet. from the wall outlet. NOTE How to remove the water scale ater Recommended descaling solutions 1. Soak in water with a descaling solution •...
  • Page 16: Care And Maintenance

    CARE AND MAINTENANCE CARE AND MAINTENANCE from UNIT Wipe with a dry, soft cloth. CAUTION Filter • Do not use volatile fluids. Lifesp Benzene paint thinner or polishing powder can damage the surface. a roo Do not use detergents. • perfo Detergent ingredients can damage the unit.
  • Page 17: Humidifying Filter

    HEPA Filter : Deodorizing Humidifying 1 unit Filter : 1 unit Filter : 1 unit KC-F30J FZ-F30HFE FZ-F30DFE FZ-F30MFE NOTE Use the date label to remind you when to replace the filter. There is the date label on the left side of the unit.
  • Page 18: Troubleshooting

    Humidity Monitor and another • If the monitor indicates TEMPERATURE, press the Display Select hygrometer in the room. Button. (Ref. E-9) ERROR DISPLAY If the error continues to occur, contact a Sharp Service Center. DIGITAL ERROR DETAILS REMEDY INDICATION Fan motor error.
  • Page 19: Specifications

    SPECIFICATIONS Power supply 220-240V 50-60Hz Fan Speed Adjustment SLEEP Fan Speed (m /hour) CLEAN AIR Rated Power (W) Noise Level (dBA) Fan Speed (m /hour) ain. Rated Power (W) CLEAN AIR &HUMIDIFY Noise Level (dBA) Humidification (mL/hour)*1 Recommended Room Size (m High density Plasmacluster ion recommended room size (m Humidifying Tray Capacity (L) Sensors...
  • Page 20: For Customer Assistance

    Sharp. Please retain your sales documentation, as this should be produced to validate a warranty claim.
  • Page 21 SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.au OR CALL SHARP 1 300 135 022 LOCAL CALL SHARP CORPORATION OF AUSTRALIA PTY LTD FOR PRODUCTS PURCHASED NEW ZEALAND CONTACT YOUR SELLING DEALER/RETAILER OR CALL SHARP CUSTOMER SERVICES TELEPHONE: 09 573 0111 FACSIMILE: 09 573 0113 WEB: www.sharpnz.co.nz...