Problems
3. Display position is incorrect.
4. Screen image is smaller or larger
than the actual screen images.
5. Vertical bars of distortion appear.
6. The characters and images have
several vertical bars on their right
side.
7. Horizontal bars of distortion appear.
8. Letters and lines appear blurred.
9. Distortion appears like the figure
below.
10. The screen is too bright or too dark.
Points to check with Possible Solutions
Adjust the image position using the <Position>
(p.26) If the problem persists, use the graphics
board's utility software to change the display
position if available.
Adjust the resolution using the <Resolution>.
(p.26)
Decrease the vertical bars using the <Clock>. (p.25)
If using the monitor in the analog input signal, try
setting the gamma value from 1.8 to 2.2. (p.31)
Decrease the horizontal bars using the <Phase>.
(p.25)
Adjust the blurred lines using <Smoothing> (p.28)
This happens when both composite (X-OR) input
signal and separate vertical synchronizing signal are
input. Please select one of the two.
Adjust the <Brightness> (The backlight of the LCD
monitor has a fixed life span. When the screen
becomes dark or begins to flicker, please contact
your dealer.)