logged in /var/log/messages, the "Hardware Error" is logged by the OS when the OS receives a request to
perform the power cutting operation, which does not indicate an failure in the server.
Ex.)
MCE 0
CPU 23 THERMAL EVENT TSC 3559f8b98fe2
TIME 1331221119 Fri Mar 9 00:38:39 2012
Processor 23 below trip temperature. Throttling disabled
STATUS 40000000882e0800 MCGSTATUS 0
MCGCAP 1000c14 APICID f SOCKETID 0
CPUID Vendor Intel Family 6 Model 45
Hardware event. This is not a software error.
It's possible to be to change the power control mode of this product to "Static mode" from "Dynamic mode" of
default and reduce the output frequency of the message.
The power control mode is established in the EM card.
■ In the case of SIGMABLADE-M(N8405-016F/016AF/016BF)
See the section of "Using Command Line Console Feature" - "Command Reference" - "srvpwrmode" in the
User's Guide of the EM card.
■ In the case of SIGMABLADE-Hv2(N8405-040F/040AF)
See the section of "Using Command Line Console Feature" - "Command Specification" - "CPU blade
management commands" - "Setting power control mode of CPU blade" and "Displaying power control
mode of CPU blade" in the User's Guide of the EM card.