First heating RIKA stoves should only be installed in rooms with normal humidity The stove body, just as various steel parts, cast iron parts and the (dry areas according to VDE 0100 Part 200)� The furnaces are not flue pipes are painted with a heat resistant paint�...
Prior to set up Note on ROOM-AIR DEPENDENT and Floor bearing capacity ROOM-AIR INDEPENDENT OPERATION: Ensure that the substructure is capable of bearing the weight of the stove prior to set-up� Your stove has been tested as a room-air independent stove according to EN13240 and to EN14785 and can be installed as well room-air dependent and independent�...
Connect at the air intake either a pipe Ø 125 mm for log wood and We recommend original flue pipes from RIKA for proper connection� combi stoves, or Ø 50 mm or Ø 60 mm for pellet stoves� Fix it with a hose clamp (not included!)�...
4. BRIEF INFORMATION ON FUEL - PELLETS Your pellet stove is only approved for the burning of pellets of tested What are pellets? quality� Please ask your pellet stove dealer for tested fuel and a list of monitored fuel manufacturers� Wood pellets are a standardised fuel�...
5. BRIEF INFORMATION ON COMBUSTIBLE - LOGS Suitable fuels and fuel amounts Output controlling Your stove is generally suitable for burning dry firewood� You can The output of your stove is regulated manually or via the Rikatronic- also burn combustibles such as wood briquettes� control�...
6. TECHNOLOGY AND SAFETY FUNCTIONS The technological advances in your new combi stove are the result of Overheating years of testing and practical experience� The practical advantages of your pellet/log stove are convincing: A safety temperature limiter (STL) switches the stove off automatically on overheating�...
7. ASSEMBLY/DISMANTLING STONE AND OPTIONS Tip the stone slightly forwards and lift it out of the floor bracing� Pay Note attention to the edges of the stone to prevent damage� Place the Only work on the unit when the mains plug has been disconnected stone on a suitable base�...
Conversion to flue pipe connection rear Swap the flue connections and the fluegas cover� Remove the left rear wall by opening the 3 top hex head bolts� Grease the fastening screw with copper paste� The rear wall is mounted at the floor, it is removed by pressing it back slightly and lifting�...
8. BURNBACK AND FLUE GAS FLAP Start of operation Refilling logs - opening flue gas flap Once the stove has been reconnected to the mains you see the Attach the wrench in shown position� following warning on the display� WARNING BURNBACK AND FLUE GAS FLAP Press the wrench inside�...
RIKA Firenet module and Amazon Alexa RIKA VOICE allows you to control your RIKA stove by simply speaking to it� Power on or off, switching between modes or adjusting the preferred heat output or room temperature: a few words is all it takes! More detailed information could be obtained at www.rika.at or from...
FIRE RISK! In a cold state, dispose it of in the household waste� Note We recommend at least once a year to have all maintenance carried out by your RIKA dealer� Cleaning the fire trough at least weekly Empty the ash drawer...
12. CLEANING Cleaning flue pipes Your RIKA dealer will gladly advise you about their service and The flue pipes should be cleaned at least 2 x a year or after approx� maintenance offers� 700 kg pellets� The flues are behind the combustion chamber�...
Dismantle the two cleaning covers behind the ash drawer by loosening the 4 milled nuts� Turn the cast cover carefully out of the frame and place it down� Vacuum out the chambers in the lower section of the flue pipes� Vacuum out the deflector section�...
13. PROBLEMS - POSSIBLE SOLUTIONS Problem 1 Problem 3 Fire burns with weak, orange flame� Pellets heap up in fire trough, Flue gas discharge when wood is added and during heating phase� window sooted up� Cause(s) pellet / log operation Cause(s) pellet operation Flue gas flap is not open for refueling Insufficient combustion air...
Please return 1 completed protocol for putting into service to blockers, lack of cleaning or maintenance and stove malfunctions� RIKA Innovative Ofentechnik GmbH, Müllerviertel 20, 4563 Thorough instruction can prevent many complaints� Micheldorf, Austria�...
Page 25
The client confirms the reception of correct and clear instructions. Our general terms and conditions shall apply. I consent to the collection, saving and use of my personal data (name, address, e-mail) by RIKA Innovative Ofentechnik GmbH for marketing and information purposes.
In cases of doubt, or in the case of missing or incorrect translations, the German version is always the sole valid version. In the interest of ensuring damage limitation in good time, the guarantee claim should be sent in writing to the RIKA specialist or contract dealer.
Page 28
Electronic Waste RIKA Innovative Ofentechnik GmbH is ensuring that its products are eco-friendly throughout the product life cycle� This is why our commitment for electronic products goes beyond the end of their product life cycle� In accordance with the European Directive (2012/19/EU) Waste Electrical and Electronic Equipment (WEEE) and other local regulations, RIKA supports the setup of take-back systems and recycling infrastructures�...
Need help?
Do you have a question about the INDUO II and is the answer not in the manual?
Questions and answers