KEY FOB MAPPING
PANEL
FUNCTION
Off (loop 2)
On (loop 3)
HONEYWELL
Left (loop 4)
Right (loop 1)
No action
Unlock
Away
2GIG
Stay
Panic (Away+Unlock)
Star
Unlock
Lock
INTERLOGIX
Lock+Lock
Panic (Lock+Unlock)
Lights
Off
Away
DSC
Stay
Panic
No action
Specifications
PHYSICAL
Housing Dimensions
Weight with Battery
Tamper Activation
Mounting Screws
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Maximum Humidity
POWER
Power Transformer
Input
Output
Part Number
Battery
Backup
Specifications
Part Number
Trickle Charge
Fast Charge
WIRELESS RADIO
RF Frequency
Compatibility
Sensors
CERTIFICATIONS
ETL Listings
RE524X
RE524XC
Other
HONEYWELL
Off
On
Left
On + Off
Right
Off
Left
On
Right
-
Off
On
Left
Right
-
8.5 x 5.0 x 1.3 inches
16.0 Ounces
Cover Opening, Wall Removal
#4 or #6
32 to 120˚F (0 to 49˚C)
-4 to 86˚F (-20 to 30˚C), Long-Term
85% relative humidity, non-condensing
100-240VAC 50/60Hz 0.5A
12VDC 1A
RE012-6
24 hours minimum
6VDC 800mAh NiMH
RE030
8mA
32mA
319.5MHz, 345MHz, 433.92MHz
Interlogix
(formerly GE
), 2GIG
®
®
Honeywell
, DSC
, Qolsys
®
®
®, Napco®
Up to 128
UL1023, ULC1023
UL1023, ULC1023, UL1610, ULC S304
FCC, IC
Tech Support Line: (877)260-5578
www.ResolutionProducts.com
2GIG
INTERLOGIX
Unlock
Away
Stay
Away+Unlock
Lock+Unlock
Star
Lock+Unlock
Unlock
Stay
Away
Away+Unlock
Star
Unlock
Away
Stay
Away+Unlock
Lock+Unlock
Star
Notices
"GE", "INTERLOGIX", "HONEYWELL", "DSC", "2GIG", "QOLSYS" AND "NAPCO" ARE TRADEMARKS OWNED
BY GENERAL ELECTRIC COMPANY, UNITED TECHNOLOGIES ELECTRONIC CONTROLS INC.,
HONEYWELL INTERNATIONAL INC., TYCO SAFETY PRODUCTS CANADA LTD, NORTEK SECURITY &
CONTROL LLC, TYCO SAFETY PRODUCTS CANADA LTD, AND NAPCO SECURITY TECHNOLOGIES, INC.
RESPECTIVELY.
RESOLUTION PRODUCTS, INC. PRODUCTS WILL FUNCTION WITH ONE OF EITHER INTERLOGIX (FOR-
MERLY GE), HONEYWELL, DSC, 2GIG OR QOLSYS SYSTEMS. HOWEVER, NO RESOLUTION PRODUCT
IS PRODUCED BY, ENDORSED BY, NOR IS OFFICIALLY ASSOCIATED WITH INTERLOGIX (FORMERLY
GE), HONEYWELL, DSC, 2GIG, QOLSYS OR NAPCO. RESOLUTION RECOMMENDS VERIFYING PROPER
ENROLLMENT AND OPERATION, PER CONTROL PANEL INSTALLATION INSTRUCTIONS, AT INSTALLA-
TION.
WARRANTY
RESOLUTION PRODUCTS, INC. WILL REPLACE PRODUCTS THAT ARE DEFECTIVE IN THEIR FIRST FIVE
(5) YEARS.
FCC NOTICE
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE.
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE THAT MAY BE RECEIVED, INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY RESOLUTION PRODUCTS, INC. COULD
VOID THE USER'S AUTHORITY TO OPERATE THIS EQUIPMENT.
FCC ID: U5X-RE524X
IC NOTICE
THIS DEVICE COMPLIES WITH INDUSTRY CANADA LICENSE-EXEMPT RSS STANDARD(S).
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE, INCLUDING INTERFERENCE THAT MAY
CAUSE UNDESIRED OPERATION OF THE DEVICE.
LE PRÉSENT APPAREIL EST CONFORME AUX CNR D'INDUSTRIE CANADA APPLICABLES AUX APPAREILS
RADIO EXEMPTS DE LICENCE. L'EXPLOITATION EST AUTORISÉE AUX DEUX CONDITIONS SUIVANTES :
(1) L' A PPAREIL NE DOIT PAS PRODUIRE DE BROUILLAGE, ET
(2) L'UTILISATEUR DE L' A PPAREIL DOIT ACCEPTER TOUT BROUILLAGE RADIOÉLECTRIQUE SUBI,
MÊME SI LE BROUILLAGE EST SUSCEPTIBLE D'EN COMPROMETTRE LE FONCTIONNEMENT.
IC: 8310A-RE524X
®
PATENTS
8,456,278
OTHER PATENTS PENDING
Specifications subject to change without notice.
This product is NOT for use with life safety sensors,
This product is NOT for use in bank installations.
Manual: 47-0014-00 REV B
Date: 12-May-16
KEY FOB
DSC
Unlock
Off
Lock
Away
Lights
Stay
Panic
Star
-
Unlock
Off
Lock
Away
Lights
Stay
Panic
Star
-
Off
Home
Away
Panic
-
Unlock
Lock
Lights
Star
such as Smoke, Heat, or CO detectors.
NAPCO
Off
On
Left (A1)
Right (A2)
-
Off
On
Left (A1)
Right (A2)
-
Off
Left (A1)
On
Right (A2)
-
Off
On
Left (A1)
Right (A2)
-
Need help?
Do you have a question about the RE524XC and is the answer not in the manual?