4) Push the threaded sleeve into the plug, screw the press nut tightly.
5) Finally, insert the AC connector into the corresponding AC receptacle on the inverter. Pay attention to the polarities
to make sure the correct assembling.
FIG. 7-7 AC receptacle
7.6 Wiring DC Input
Note: The DC connectors are in paired (negative and positive ones). Pay attention to the polarities when assembling.
7.6.1 Requirement for DC input
This single-phase inverter is equipped with two MPP trackers.
Requirements for PV module strings:
1) Same type PV modules for each string.
2) The power, voltage (startup and open-circuit voltage) and operating current of each PV strings must meet the
allowable value of the inverter.
Note: Consider temperature coefficient of the PV modules.
Check the inverter specification in section Appendix B.
7.6.2 Wiring
Negative Coupler & Contactor Pin
10 / 17
FIG. 7-5 AC Terminal Positions
FIG. 7-6 Tightening the AC Connector
FIG. 7-9 DC Input Connectors
FIG. 7-10 Structure Illustration of DC Connector
PE
N
L
FIG. 7-8 Installing the AC Connector
Positive Coupler & Contactor Pin.
7 Electrical Connection