Dimensions Of Stream Compressors; Models - Emerson Copeland 4MF-13X Application Manuallines

Stream semi-hermetic compressors
Hide thumbs Also See for Copeland 4MF-13X:
Table of Contents

Advertisement

Once a new system design is set and assembled, a functional test is required. The functional test
includes a qualification for the general system oil return. Systems with multiple compressors (two,
three, or more) require additional oil balancing qualification between the parallel compressors.
System engineers should review the system design and operation to identify the critical conditions
and to check oil return and oil balancing. Typically, the following situations should be considered:
▪ In single compressor systems: to check oil return, testing conditions shall be at minimum mass
flow and minimum density of suction gas in continuous and frequent start/stop-cycling.
▪ In multiple compressor systems: to check oil return and oil balancing in the tandem or rack,
testing conditions shall be at the corner points of the system application envelope in continuous
and frequent start/stop-cycling.
▪ The system shall also be tested with regards to liquid refrigerant floodback and the superheat
level of the refrigerant gas at compressor suction.
These checks should be carried out for standard operation, but also for special conditions such as
compressor frequent start/stop, compressor start after long off time with migration, defrost, low load,
load changes, fans or pumps cycling at low load and more.
2.6

Dimensions of Stream compressors

2.6.1 4M* models
Figure 9: 4M* compressors dimensions
A
Compressor
(mm)
4MF-13X
4MA-22X
637
4ML-15X
4MH-25X
4MM-20X
662
4MM-20X
4MT-22X
4MJ-33X
662
4MU-25X
4MK-35X
692
Table 4: 4M* compressors dimensions
AGL_Stream_ST_A2L_A1_4M_6M_EN_Rev00
B
C
D
(mm)
(mm)
(mm)
145
88.5
355.9
170
99.4
376.2
170
99.4
376.2
200
131.4
380
G
(mm)
354.6
354.8
354.8
354.8
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents