Mitsubishi Electric AHU-KIT-SP Manual page 24

Air handling unit interface
Table of Contents

Advertisement

Data address
Item
31001
Connection status:Slave1
31002
Connection status:Slave2
31003
Connection status:Slave3
31004
Connection status:Slave4
31005
Connection status:Slave5
31006
Connection status:Slave6
31007
Connection status:Slave7
31008
Connection status:Slave8
31009
Connection status:Slave9
31010
Connection status:Slave10
31011
Connection status:Slave11
31012
Connection status:Slave12
31013
Connection status:Slave13
31014
Connection status:Slave14
31015
Connection status:Slave15
31016
Capacity command(Master)
31017
Capacity command(Slave1)
31018
Capacity command(Slave2)
31019
Capacity command(Slave3)
31020
Capacity command(Slave4)
31021
Capacity command(Slave5)
31022
Capacity command(Slave6)
31023
Capacity command(Slave7)
31024
Capacity command(Slave8)
31025
Capacity command(Slave9)
31026
Capacity command(Slave10)
31027
Capacity command(Slave11)
31028
Capacity command(Slave12)
31029
Capacity command(Slave13)
31030
Capacity command(Slave14)
31031
Capacity command(Slave15)
Initial
Range
Units
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
0:Unconnected 1:Connection
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
0
0 ~ 65535
1 %/count
0 ~ 100%
Notes
[Master/slave1~15]
<SW1 AHU interface address>
SW1:0=master
SW1:1=AHU interface No.1 (slave 1)
SW1:2=AHU interface No.2 (slave 2)
SW1:3=AHU interface No.3 (slave 3)
SW1:4=AHU interface No.4 (slave 4)
SW1:5=AHU interface No.5 (slave 5)
SW1:6=AHU interface No.6 (slave 6)
SW1:7=AHU interface No.7 (slave 7)
SW1:8=AHU interface No.8 (slave 8)
SW1:9=AHU interface No.9 (slave 9)
SW1:A=AHU interface No.10 (slave 10)
SW1:B=AHU interface No.11 (slave 11)
SW1:C=AHU interface No.12 (slave 12)
SW1:D=AHU interface No.13 (slave 13)
SW1:E=AHU interface No.14 (slave 14)
SW1:F=AHU interface No.15 (slave 15)
MODEL NAME
Air Handling Unit Interface
MODEL TYPE
AHU-KIT-SP
ISSUE
CLASSIFICATION
SPECIFICATION
MORIKAWA
DWG NO.
REV.MARK PAGE
PSZ000Z308
21.09.17
24/38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents