LEED and Green Globes certified, as well as having achieved ENERGY STAR Building status. Start-up & Operation ....15 In 2010, RenewAire joined the Soler & Palau (S&P) Ventilation Group in order to provide direct access to the Maintenance .....16-17 latest in energy-efficient air-moving technologies.
Page 3
One inch foil-faced EPS foam throughout. DEFROST Passive frost-free design under most DUCT CONNECTIONS residential conditions. EV130, EV200 & EV240 - Insulating double collars with six-inch/eight-inch round connections for WARRANTY flexible or rigid duct work. Ten year limited warranty on energy exchange core;...
Page 4
Efficiency % Heating 0° 32° Total Adjusted Total EV130, EV200, EV240 AND EV300 Cooling Recovery Efficiency % Recovery Efficiency % 35° 95° Electrical Requirements Volts 120 Amps 0.35 Exhaust Air Transfer Ratio = 2.0% @ 0.2 in. wg (50 PA) and 2.0% @ 0.4 in. wg (100 Pa)
Page 5
Percentage timer control with 10 1/2" x 10 1/2" x 1" Download specification at: furnace interlock (FM) renewaire.com/specifications Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on the EV130. ELECTRICAL DATA UNIT PERFORMANCE CORE PERFORMANCE Volts...
Page 6
0.30 72/58 0.20 71/57 0.10 70/56 * See HVI certification ratings on page 148 of RenewAire’s Full Line Volume XVII Catalog. UNIT DIMENSIONS AIRFLOW CONFIGURATION Available as shown in dimension drawing. ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake 33 1/4"...
Page 7
67/53 0.30 66/52 0.20 65/51 0.10 64/50 * See HVI certification ratings on page 148 of RenewAire’s Full Line Volume XVII Catalog. UNIT DIMENSIONS ABBREVIATIONS AIRFLOW CONFIGURATION EA: Exhaust Air to outside 33 1/4" Overall OA: Outside Air intake Available as shown in dimension drawing.
Page 8
71/57 69/55 66/51 65/49 63/47 62/46 * See HVI certification ratings on page 148 of RenewAire’s Full Line Volume XVII Catalog. UNIT DIMENSIONS AIRFLOW CONFIGURATION Available as shown in dimension drawing. ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake 33 5/8"...
EV130, EV200, EV240 AND EV300 INSTALLATION BEFORE YOU BEGIN PLANNING YOUR INSTALLATION Read all instructions before installing the unit. Also review supplemental instructions included with any controls that will be installed. Carefully unpack and inspect the unit for shipping damage. Open the access door and inspect inside the unit.
Page 10
The Exhaust Air Duct and the Outside Air Duct connect the unit to the outside. Flexible insulated duct is typically used. See Duct Sizes. DUCT SIZES EV130 - 6" round insulated duct, 8" round insulated duct may be used to maintain maximum airflow Exhaust Air & Outside Air (EA & OA) EV200, EV240 and EV300 - 8"...
Page 11
INSTALLATION APPLICATIONS PLANNING YOUR INSTALLATION See figures F2-F5 for examples of some common installation approaches (EV130 shown). Separate Room Air Pick-up - Separate Air and Fresh Air Supply Fresh Air to Furnace Return Air Trunkline Note: ERV blower may be operated separate from furnace blower.
Page 12
EV130, EV200, EV240 AND EV300 INSTALLATION PLANNING WARNING YOUR INSTALLATION RISK OF FIRE, ELECTRIC SHOCK, OR INJURY. OBSERVE ALL CODES AND THE FOLLOWING: 1. Before servicing or cleaning the unit, unplug 9. Sufficient air is needed for proper combustion the unit line cord. Make sure unit is not running and exhausting of gases through the flue before opening its door.
Page 13
EV130, EV200, EV240 AND EV300 INSTALLATION MOUNTING THE UNIT INSTALLATION INSTRUCTION Unit may be installed in any orientation Mounting the ERV to a stud wall Orient the unit for the simplest duct layout and connections. Note however that the door...
Page 14
EV130, EV200, EV240 AND EV300 INSTALLATION INSTALLING OUTSIDE AIR AND EXHAUST AIR DUCTS INSTALLATION INSTRUCTION Ducts connecting the unit to the outside must be well-insulated. Band or tape inner duct liner to inner flange of appropriate collar. Drive a sheet metal screw through liner to CAUTION secure duct spiral wire to collar.
INSTALLING CONTROLS Optional controls: RenewAire offers a variety of controls specifically designed to work with the EV130/200/240/300 products. These include: PTL (a two wire percentage timer), FM (a six wire percentage timer that will interconnect with the furnace blower), and PBL (point of use push button control). Other controls that throw an unpowered switch may also be used.
EV130, EV200, EV240 AND EV300 MAINTENANCE SERVICE PARTS EV130, EV200, EV240 AND EV300 www.renewaire.com (800) 627- 4499 support@renewaire.com RENEWAIRE.COM 1.800.627.4499 INSTALLATION, OPERATION AND MAINTENANCE MANUAL...
Page 17
NOTE: The filters should be replaced after they have been cleaned several times. The primary contact for EXCHANGE CORE. replacement filters for your RenewAire unit is the installing contractor. As an alternative, you may wish to Keep it away from water or fire to produce your own filters.
Page 18
EV130, EV200, EV240 AND EV300 NOTES RENEWAIRE.COM 1.800.627.4499 INSTALLATION, OPERATION AND MAINTENANCE MANUAL...
Page 19
EV130, EV200, EV240 AND EV300 NOTES 1.800.627.4499 INSTALLATION, OPERATION AND MAINTENANCE MANUAL RENEWAIRE.COM...
Page 20
Every time. Anywhere. At RenewAire — unlike other ventilation suppliers — advanced ventilation solutions are all we do. Our sole passion. Which is why for all commercial projects, we are the “V” in HVAC...