Wiring Diagram: Outdoor Unit - Daikin RZAG100M7V1B Installer's Reference Manual

Hide thumbs Also See for RZAG100M7V1B:
Table of Contents

Advertisement

Compressor
Distributor
Liquid receiver
12.4

Wiring diagram: Outdoor unit

The wiring diagram is delivered with the unit, located at the inside of
the service cover.
(1) Connection diagram
English
Connection diagram
Only for ***
See note ***
Outdoor
Indoor
Upper
Lower
Fan
ON
OFF
(2) Layout
English
Layout
Front
Back
Position of compressor terminal
(3) Notes
English
Notes
X1M
1
NOTES:
1
Refer to the wiring diagram sticker (on the back of the front
plate) for how to use the BS1~BS3 and DS1 switches.
2
When operating, do not short-circuit protective devices S1PH
S1PLand Q1E.
3
Refer to the combination table and the option manual for how
to connect the wiring to X6A, X28A and X77A.
4
Colours: BLK: black, RED: red, BLU: blue, WHT: white, GRN:
green
RZAG71~140M_V1+Y1
Sky Air Alpha-series
4P486046-1A – 2017.08
Translation
Connection diagram
Only for ***
See note ***
Outdoor
Indoor
Upper
Lower
Fan
ON
OFF
Translation
Layout
Front
Back
Position of compressor terminal
Translation
Notes
Connection
Indoor/outdoor communication
Earth wiring
Field supply
Several wiring possibilities
Protective earth
Field wire
Wiring depending on model
Option
Switch box
PCB
Flare connection
A
Field piping (liquid: Ø9.5 flare connection)
B
Field piping (gas: Ø15.9 flare connection)
Heating
Cooling
(4) Legend
English
Legend
Field supply
Optional
Part n°
Description
A1P
Printed circuit board (main)
A2P
Printed circuit board (noise filter)
BS1~BS3 (A1P)
Push button switch
C1~C5 (A1P) (Y1
Capacitor
only)
DS1 (A1P)
Dipswitch
E1H
Bottom plate heater (option)
F*U
Fuse
HAP (A1P)
Light-emitting diode (service monitor is
green)
K1M, K3M (A1P) (Y1
Magnetic contactor
only)
K1R (A1P)
Magnetic relay (Y1S)
K2R (A1P)
Magnetic relay (Y2S)
K4R (A1P)
Magnetic relay (E1H)
K10R, K13R~K15R
Magnetic relay
(A1P)
K11M (A1P) (V1
Magnetic contactor
only)
L1R (Y1 only)
Reactor
M1C
Compressor motor
M1F~M2F
Fan motor
PFC (A1P) (V1 only)
Power factor correction
PS (A1P)
Switching power supply
Q1DI
Earth leakage circuit breaker (30 mA)
Q1E
Overload protection
R1~R8 (A1P) (Y1
Resistor
only)
R1T
Thermistor (air)
R2T
Thermistor (discharge)
R3T
Thermistor (suction)
R4T
Thermistor (heat exchanger)
R5T
Thermistor (heat exchanger middle)
R6T
Thermistor (liquid)
R7T
Thermistor (fin)
R8 (A1P) (V1 only)
Resistor
RC (A1P) (Y1 only)
Signal receiver unit
S1PH
High pressure switch
S1PL
Low pressure switch
SEG1~SEG3
7-segment display
12 Technical data
Translation
Legend
Field supply
Optional
Part n°
Description
Installer reference guide
31