SECTION V: OPERATION (cont .)
MEASURING THE OUTCOMING WATER TEMPERATURE (cont.)
This log (or a similar one) should be filled out as follows:
Date
Time

SECTION VI: MAINTENANCE

NOTICE TO THE OWNER: If you are having a mechanical problem with your water heater,
contact your service company or installer.
WATER PIPING
On an annual basis, all piping should be checked for leakage at joints, shut-off valves, and
unions.
T&P RELIEF VALVE
On an annual basis, the temperature and pressure relief valve should be checked for proper
operation. First, attach a drain line to the valve to direct the water discharge to an open drain.
This is very important because the temperature of the discharge could be very hot. Second,
lift the lever at the end of the valve several times. The valve should operate freely and return
to its original position properly. If water does not flow out of the valve, remove and inspect
for corrosion or obstructions. Replace with a new valve if necessary. Do not repair the faulty
valve as this may cause improper operation.
ANODE RODS
Anode rods should be inspected twice in the first year and at least yearly once a time interval
for inspection has been developed. It is recommended to check the rod(s) six months after the
heater is installed. If the anode rod had reduced in size by two-thirds of its original diameter
of 3/4" or shows signs of pitting, it is time for replacement. Take the following steps when
changing the anode rod(s):
1. Shut off water supply.
2. Open any faucet to relieve tank pressure.
3. Remove caps on water heater top; push insulation aside.
4. Use a 1 1/16" six-sided socket wrench and a breaker bar. Snap hard to break the anode rod
seal.
5. Remove rod(s) and replace with new rod(s).
6. Turn water supply back on and leave faucet open until air is out of line.
7. Turn faucet off and check that new rod(s) doesn't leak.
8. Snap caps back into place.
FLUSH THE TANK
Elements in the water such as lime and iron may accumulate in the heater. Accumulation of
these elements can keep your water heater from operating at peak efficiency and may lead to
premature tank failure. It is recommended that the tank is drained and flushed thoroughly
once a year to prevent buildup.
Person running test
Set temp °F
Outlet temp °F
Page 33