64 installation
INSTALLATION OF THE APPLIANCE
Underbench oven
Your underbench oven looks best when the control panel
is directly under the benchtop. An upper infill panel may
be added if the cooktop placed above the benchtop is too
deep. Refer to cooktop installation instructions for required
clearance between cooktop and oven.
IMPORTANT!
Note: Dimension'D'*
A requirement for all EVEPxxxx pyrolytic clean ovens and
Duo ovens – for proper ventilation there must be a gap
at the bottom rear of the cabinet. This can be a full width
opening 20mm deep.
Power point connection for the EVEP615 and EVEP618
must be accessible with the appliance fully installed. If
the supply cord is damaged it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
Cut-out dimensions
type of fit
A (width)
Flush fit (mm)
Proud fit (mm)
Double oven Cut-out dimensions
type of fit
A (width)
Flush fit (mm)
Proud fit (mm)
650mm
min.
B (height)
C (depth)
600
600
581 min.
568
590
560 min.
561mm
596mm
B (height)
C (depth)
600
1086
581 min.
568
1078
560 min.
561mm
596mm
Pyrolytic underbench cut-out dimensions
type of fit
Flush fit (mm)
Duo oven cut-out dimensions
type of fit
Flush fit (mm)
650mm
min.
mounting
holes 582mm
mounting
holes 582mm
mounting
holes 582mm
A (width) B (height)
C (depth)
600
600
581 min.
561mm
596mm
A (width) B (height)
C (depth)
600
893
581 min.
561mm
D
mounting holes
fit countersunk screws
with plastic spacers
provided
D*
20
mounting
holes 582mm
D*
20
mounting holes
582mm
fit long screws
provided