RF bit rate 10,000 bps. In order to overcome the interference that may be encountered in harsh environments, the LRA-900 allows the RF transmission bit rate to be configured to a minimum of 250 bps, enhancing the capability of the modem to resist noise and other interference.
Step 2: Install .NET Framework 3.5 component The LRA-900 Utility tool requires the “.NET Framework 3.5 components”. If your PC’s environment does not has “.NET Framework 3.5 components”, it will start to install .NET Framework 3.5 components from the web site, after executing the “Setup.exe” file.
Page 11
After installing the .Net Framework components, the software will continue to install the Utility tool. Click the “Next” button to continue. Select the installation path of the LRA-900 Utility and click the “Next” button. LRA-900 (RS-232/RS485 to LoRa Radio Modem) User Manual Version 1.0.1 Page:...
After installing the utility tool, please follow the following steps to set up the communication between the Utility and the LRA-900. Step 1: Connect the PC available COM port with the RS-232 port of the LRA-900 device via CA-0910 cable. Users can find the communication cable (CA-0910) in the product box.
Page 14
Step 3: Execute the LRA-900 Utility tool. Step 4: Select the necessary PC’s COM Port which connected with the LRA-900 module. And then press the ‘Open’ button to connect with module. Step 5: After successfully connected with the module, all device parameters will be shown as below picture.
Page 17
0 ~ 15 dBm. Step 7: Press the save button to save all device parameters into module Step 8: After setting, switch the LRA-900 “Init.” Switch to “Off” position and reboot the module. LRA-900 (RS-232/RS485 to LoRa Radio Modem) User Manual Version 1.0.1...
3.3. LRA-900 RSSI Test By using the utility tool (v1.10), user can follow the following steps to set up the communication between the Utility and the LRA-900 and check the RSSI information between these two devices. Step 1: Let the module into “Init” mode and use Utility tool to enable the two LRA-900s’...
Page 19
Step 2: After setting, let the two modules into “Normal” mode. Then connect the LRA-900#2’s RS-232 Tx pin with Rx pin. Step 3: Connect PC with LRA-900#1 and use Utility tool’s “Test” mode to test the RSSI info. of these two devices.