Download Print this page

ICP DAS USA RFU-433 Quick Start Manual

Hide thumbs Also See for RFU-433:

Advertisement

Quick Links

RFU-433 Quick Start
What's in the box?
In addition to this guide, the package includes the following items:
RFU-400 Module + ANT-104-02
1. Specifications & Features
Frequency Range: 433.1 MHz ~ 434.6 MHz (default channel is 4: 433.5 MHz)
Channel Spacing: 100 kHz
Channel Number: 16
Output Power: Default 10 dBm, Max 19 dBm
Modulation Technique: 2GFSK
Group ID: 0 ~ 7
RF Data Rate: 650 ~ 57600 bps
Communication distance: 1000 m ( in open areas with 9600 bps RF Data Rate )
Antenna Connector: RPSMA
Serial Port: COM 0 ( RS-232 and RS-485 bypass )
COM Port Data Rate: 1200 ~ 115200 bps
COM Port Data Format: N,8,1 / O,8,1 / E,8,1
Support RF Repeater Mode
LED: PWR, RF_Tx, RF_Rx
2500 Vrms photocouple isolation on power.
±4 kV ESD to contact.
Reverse polarity protection and Short protection on power.
Power requirement +10 V
Power consumption 1 W @ 24 V
Operating Temperature: -25℃ ~ +75℃.
Storage Temperature: -30℃ ~ +80℃.
Humidity: 10 to 90% RH (Non-condensing)
Module Dimensions (not include antenna): 33 mm x 106 mm x 85 mm (W x L x H)
Antenna Dimension: 108 mm x Ø 10mm
RFU-433 Quick Start v1.00, January 11, 2019
~ +30 V
.
DC
DC
.
DC
V1.00, Dec. 2018
Screwdriver
-------------------------------------
1

Advertisement

loading

Summary of Contents for ICP DAS USA RFU-433

  • Page 1 Humidity: 10 to 90% RH (Non-condensing)  Module Dimensions (not include antenna): 33 mm x 106 mm x 85 mm (W x L x H)  Antenna Dimension: 108 mm x Ø 10mm RFU-433 Quick Start v1.00, January 11, 2019 -------------------------------------...
  • Page 2 * If COM rate is 115200 bps, the RF rate will set to 57600 bps. Switch Name Baud rate (bps) Baud rate (bps) 115200 57600 38400 19200 9600 4800 2400 1200 8 ~ E reserved COM Rate RFU-433 Quick Start v1.00, January 11, 2019 -------------------------------------...
  • Page 3 “Output Power” parameter will be fixed at 10 dBm, and the “Message Duty” parameter will be fixed at enable 10% message duty. If use “Software Setting”, the “Channel”, “Output Power” and “Message Duty” parameters can be set by users. RFU-433 Quick Start v1.00, January 11, 2019 -------------------------------------...
  • Page 4 PC can control RS-485 modules 1 ~ 3 through a RFU-433. And control modules 4 ~ 6 through another RFU-433. If these two RFU-433 are far away. Users can add a RFU-433 with repeater mode between these two RFU-433. RFU-433 Quick Start v1.00, January 11, 2019 -------------------------------------...