Whirlpool CAE2745 Manual page 9

Commercial washers
Table of Contents

Advertisement

Available languages

Available languages

MANUAL OVERVIEW TEST MODE — See page 4 to access Manual Overview Test Mode.
Pressing the START button will activate/deactivate each output. When the output is activated, the corresponding Status LEDs
will flash. IMPORTANT: Lid must be closed and locked to perform SPIN & AGITATE tests.
OUTPUT
Output Details
NOTE: Outputs will time-out after 5 minutes.
LID LOCK
Lock and unlock the lid. NOTES: When lock is enabled, the "Lid Locked" LED will turn ON. Will only lock when lid is closed.
Will only unlock when basket RPM is 0. If lid is not closed, washer will flash status LEDs on and off.
• If lid does not lock or unlock, go to TEST #8: Lid Lock, page 18.
COLD VALVE
Turns ON and turns OFF cold water valve.
• If valve does not turn on, go to TEST #2: Valves, page 13.
HOT VALVE
Turns ON and turns OFF hot water valve.
• If valve does not turn on, go to TEST #2: Valves, page 13.
UNUSED
UNUSED
UNUSED
UNUSED
DRAIN
Turns ON and turns OFF the drain pump.
• If pump does not turn on, go to TEST #7: Drain Pump, page 17.
UNUSED
LOW SPIN – To perform test, lid must be closed and locked.
Spins basket from 0 to 500 RPM. NOTE: Allow up to 15 seconds for shifter to reposition.
IMPORTANT: To activate Low Spin, RPM must read "0" and lid must be closed with lid lock enabled.
If lid is not closed, status LEDs will flash on and off. IMPORTANT: Water in tub must be drained before test.
• If motor does not spin, go to TEST #3a & 3b: Drive System (Shifter & Motor), pages 13 & 14.
HIGH SPIN – To perform test, lid must be closed and locked.
Spins basket from 0 to maximum RPM. NOTE: Allow up to 15 seconds for shifter to reposition.
IMPORTANT: To activate High Spin, RPM must read "0" and lid must be closed with lid lock enabled.
If lid is not closed, status LEDs will flash on and off. IMPORTANT: Water in tub must be drained before test.
• If motor does not spin, go to TEST #3a & 3b: Drive System (Shifter & Motor), pages 13 & 14.
GENTLE AGITATION – To perform test, lid must be closed and locked.
Shifts from idle motor to gentle CW/CCW agitation. NOTE: Allow up to 15 seconds for shifter to reposition.
IMPORTANT: To activate Gentle Agitation, RPM must read "0" and lid must be closed with lid lock enabled. If lid is not closed,
status LEDs will flash on and off.
• If motor does not agitate, go to TEST #3a & 3b: Drive System (Shifter & Motor), pages 13 & 14.
HEAVY AGITATION – To perform test, lid must be closed and locked.
Shifts from idle motor to heavy CW/CCW agitation. NOTE: Allow up to 15 seconds for shifter to reposition.
IMPORTANT: To activate Heavy Agitation, RPM must read "0" and lid must be closed with lid lock enabled. If lid is not closed,
status LEDs will flash on and off.
• If motor does not agitate, go to TEST #3a & 3b: Drive System (Shifter & Motor), pages 13 & 14.
DO NOT REMOVE OR
DESTROY
FOR SERVICE TECHNICIAN'S USE ONLY
= ON
STATUS LEDs
1
2
2
1
4
4
1
4
2
4
2
1
8
8
1
On
2
8
On
On
8
2
1
On
8
4
PAGE 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cae2765Cae2795Qcae2735Mat20csMat20mn