TROUBLESHOOTING TESTS

TEST #1: Main Control
This test checks for incoming and outgoing supplies to and
from the main control. This test assumes that proper voltage
is present at the outlet.
1. Unplug washer or disconnect power.
2. Remove console to access main control.
3. Verify that ALL connectors are inserted all the way into the
main control.
4. Plug in washer or reconnect power.
5. With a voltmeter set to AC, connect black probe to J7-3
(Neutral) and red probe to J7-1 (L1).
= represents pin-1
PAGE 12
FOR SERVICE TECHNICIAN'S USE ONLY
Main Control Board Connectors & Pinouts (Figure 3)
J2
J2-5
OPEN
J2-4
BLK
+13VDC
J2-3
GRY
-5VDC (CIRCUIT GND)
J2-2
PNK
RPM INPUT
J2-1
BLU
SHIFTER POSITION INPUT
J3
J3-10 BLK
TEMP THERMISTOR INPUT (HYBRID)
J3-9
BLK
TEMP THERMISTOR GND (HYBRID)
J3-8
OPEN
J3-7
OPEN
J3-6
OPEN
J3-5
BLU
COLD VALVE (L1)
J3-4
RED
HOT VALVE (L1)
J3-3
OPEN
J3-2
OPEN
J3-1
WHT
NEUTRAL
J4
J4-3
BLU
PRESSURE TRANSDUCER INPUT
J4-2
OPEN
J4-1
BLU
-5VDC (CIRCUIT GND)
J7
J7-3
BLK
NEUTRAL
J7-2
GRN
CHASSIS GROUND
J7-1
BLK
L1
J4-Pressure Transducer
Diagnostic
LED
J7-Power
Cord
J7
J16-PSC Motor/Drain
 I f 120VAC is present, go to step 6.
 I f 120VAC is not present, check the AC power cord
for continuity (See Figure 9).
6. Is the "Diagnostic LED" ON or OFF? (See Figure 3 below
for LED location.)
 O N: (+5VDC present) continue to step 7.
 O FF: (+5VDC missing) proceed to step 8.
7. With a voltmeter set to DC, connect black probe to J2-3
(Circuit Gnd) and red probe to J2-4 (+13VDC).
 If +13VDC is present, main control supplies are good.
 If +13VDC is not present, go to step 8.
J10
J10-6 BLK
J10-5 BLK
J10-4 BLK
J10-3 BLK
J10-2 BLK
J10-1 BLK
J11
J11-6 RED
J11-5 RED
J11-4 RED
J11-3 RED
J11-2 RED
J11-1 RED
J15
J15-4 RED
J15-3 WHT
J15-2 BLU
J15-1 YEL
J16
J16-7 ORN
J16-6 RED
J16-5
J16-4 WHT
J16-3 LT BLU DRAIN PUMP MOTOR (L1)
J16-2 W/ BLU SHIFTER MOTOR (NEUTRAL)
J16-1 BRN
J2-Shifter
J11-Rotary Encoders *
J11
J4
J10
J2
J16
J15
J15-Lid Lock
ROW 2
ROW 3
COLUMN 0
COLUMN 1
COLUMN 2
COLUMN 3
ROW 4
ROW 5
COLUMN 0
COLUMN 1
COLUMN 2
COLUMN 3
LOCK SWITCH
NEUTRAL
LID SWITCH INPUT
LOCK SWITCH SOLENOID (L1)
MOTOR CCW WINDING (L1)
MOTOR CW WINDING (L1)
OPEN
MOTOR (NEUTRAL)
SHIFTER MOTOR (L1)
J10-Rotary
Encoders
J3-Temperature
Sensor/Valves
J3
* Not available on all models
DO NOT REMOVE OR DESTROY