Whirlpool CAE2745 Manual page 4

Commercial washers
Table of Contents

Advertisement

Available languages

Available languages

QUICK OVERVIEW TEST MODE (Page 8)
To access Quick Overview Test Mode, perform steps 1 and 2 of
Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
 "Final Spin" LED On
In
Soak/
Use
Wash
NOTE: Status LED names may vary between makes and models.
Press the START button to begin the Quick Overview test. See
page 8 for order of Quick Overview test.
U pon entering the Quick Overview test mode, the washer will
perform an automatic test with water cycles to check major
washer functions.
P ressing the START button will manually advance to the
next step.
P ress and hold the START button for 3 seconds at any time
to exit any test mode.
IMPORTANT: Lid must be closed with lid lock enabled
to perform test.
MANUAL OVERVIEW TEST MODE (Page 9)
To access Manual Overview Test Mode, perform steps 1 and 2
of Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
 "Final Spin & Done" LEDs On
In
Soak/
Use
Wash
Press the START button to enter Manual Overview Test Mode.
See page 9 for Manual Overview Test Mode.
U pon entering the Manual Overview test mode, the washer
will have all outputs OFF.
T he cycle selector knob is used to select the output
to be tested.
T he START button will activate/deactivate the selected output.
W hen the selected output is activated, the corresponding
status LEDs flash ON & OFF.
P ress and hold the START button for 3 seconds at any time
to exit any test mode.
IMPORTANT: As a safety feature, the lid must be closed
with lid lock enabled to activate either Agitate or Spin Test.
NOTE: Multiple outputs may be activated simultaneously.
NOTE: Outputs left on will time-out after 5 minutes.
CALIBRATION MODE
IMPORTANT: Calibration must be performed when any of
the following components have been replaced: Main Control,
Basket, Drive Assembly, Suspension, Motor, and Capacitor.
Calibration should also be performed when the washer is moved
to a different location or, more specifically, to a different power
outlet. Not performing calibration may result in poor wash
performance.
To access Calibration Mode, perform steps 1 and 2 of Activating
the Service Diagnostic Test Modes. Toggle the cycle selector
knob until the status LEDs correspond as follows:
 "Rinse" LED On
In
Soak/
Use
Wash
PAGE 4
FOR SERVICE TECHNICIAN'S USE ONLY
Final
Rinse
Spin
Done
Final
Rinse
Spin
Done
Final
Rinse
Spin
Done
NOTE: Status LED names may vary between makes and models.
Press the START button to begin washer calibration. All status
LEDs will turn on.
D o NOT interrupt calibration, disturb washer, or remove
power; otherwise, calibration must be repeated.
L id must be down to perform test.
B asket must be empty to perform test (no water or clothes).
C alibration cycle runs for approximately 2–4 minutes.
Cycle completes when door unlocks and washer enters
standby mode.
DRAIN & SPIN CYCLE
To access the Drain & Spin Cycle, perform steps 1 and 2
of Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
 "Rinse & Done" LEDs On
In
Soak/
Use
Wash
Press the START button to start the Drain & Spin Cycle.
UI TEST MODE
To access UI (User Interface) Test Mode, perform steps 1 and 2
of Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
 "Rinse & Final Spin" LEDs On
(1)In
(2)Soak/
Use
Wash
NOTE: Status LED names may vary between makes and
models. Use LED # identifications.
Press the START button to begin the UI test.
U pon entering the UI test mode, all status LEDs will be
turned ON.
P ressing the START button will turn on and off all status
LEDs, or toggle the state of each status LED independently.
(Example: if 2 are on, and 3 are off, then 2 will be turned off
and 3 turned on.)
W hen toggling the cycle selector knob, each double click
will toggle the "Done" (5) LED.
T urning the rotary switch will toggle the following status LED
on and off.
• (1) In Use LED
P ress and hold the START button for 3 seconds.
W asher will exit UI test mode after 5 minutes of inactivity
or unplugging the power cord.
Final
Rinse
Spin
Done
(4)Final
(3)Rinse
Spin
(5)Done
DO NOT REMOVE OR DESTROY

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cae2765Cae2795Qcae2735Mat20csMat20mn

Table of Contents