During the periods of inactivity of the equipment it is advisable to disconnect the plug from the socket,
carefully clean the cabinet as it is done during periodic cleaning and let the air circulate in the
refrigerated compartment covering it with a cloth cloth.
7. BEHAVIOUR IN CASE OF FAILURE
If the appliance is not working, check that the plug is correctly inserted into the socket and that the
power cord is not damaged.
If the set temperature is not reached, make sure that the control switch is on, the control unit is
regulated, the appliance is not defrosting or recovering after defrosting, the condenser is not clogged
by dust, the appliance is well ventilated and is not near heat sources, food stored inside does not
obstruct air recirculation and/or the correct closure of the cabinet, the appliance does not work in
abnormal conditions.
If the unit leaks water, check that the water drain is not damaged and that the drain has been drained
and not obstructed. Also check that the device is leveled.
If the unit is noisy, check that there are no unscrewed screws or bolts; that the unit is level and level.
CAUTION: If after all these checks, the fault persists, contact technical support.
8. ACTIVITIES BY SPECIALIZED PERSONNEL
When replacing components by qualified personnel, ensure that the mains plug is disconnected.
9. DISPOSAL
Disposal of the appliance must be carried out by specialised companies in accordance with the laws