Mounting The Combiplus; Combiplus Installation Options - Viessmann CombiPLUS Kit Installation & Quick Start Manual

Table of Contents

Advertisement

Installation

Mounting the CombiPLUS

K
A
J
I
4
J
I

CombiPLUS installation options

Shown is the maximum distance between the boiler
and CombiPLUS using field supplied fittings and pipes.
Note: The maximum distance between the boiler and the
CombiPLUS is restricted by the communication
cable to 36" (915 mm).
6
1
2
3
K
CombiPLUS Kit for Vitodens 100-W, WB1B Quick Start
Prepare the wall and mount the CombiPLUS A
using the supplied template and mounting hardware.
1
Pull the bottom of the boiler away from the wall
approximately 1/2" (12 mm) and slide the top of the
CombiPLUS mounting template T between the wall
and the boiler. Release the boiler and allow the weight
of the boiler to hold the template in place.
The top outline on the template shows the lower
imprint of the boiler (shown in dotted lines). Adjust
the template to the boiler in this position when
connecting the 12" flex piping.
The second outline on the template shows the lower
imprint of the boiler (shown in solid lines). Adjust the
template to the boiler in this position when connecting
the 7" flex piping.
2
Drill a hole through the top mounting hole as shown
on the template (x2). Drill a hole in the centre of the
slot as shown on the template (x2).
Remove the template.
3
Install the supplied anchors K into the wall (if
required).
4
Install the supplied washers J on to the lag bolts I.
Install the lag bolts/washers into the wall anchors
(if used) and through the slots of the CombiPLUS A.
Note: Leave the lag bolts loose enough to allow
up and down adjustments in the slot.
T
Note: Refer to the installation Instructions for
additional mounting options.

Advertisement