Viessmann CombiPLUS Kit Installation & Quick Start Manual page 14

Table of Contents

Advertisement

Operation
Programming
3
4
14
1
2
CombiPLUS Kit for Vitodens 100-W, WB1B Quick Start
Programming the boiler control for operation
with or without the CombiPLUS.
Note: If an optional CombiPLUS is used, the
boiler control must be programmed.
For additional programming refer to the
boiler Operating, Installation and
Service Instructions.
1
Lift flap and pull control unit cover down.
All boiler controls are located behind the
control unit cover.
2
Simultaneously turn rotary selectors "
and "tr" to their central position.
"SERV +
Note: If one (or both) of the rotary selector
dials are already in the central position,
take it (or them) out of the central
position and then simultaneously
turn both rotary selectors back to
the central position.
3
Turn the rotary selector "
the right. "
4
Adjust the control by turning the rotary
selector "tr".
The display shows: "0" or "1" flashing
"1" boiler with the optional CombiPLUS.
"0" boiler without optional CombiPLUS
(factory default setting).
Note: After programming the boiler control to
accept the CombiPLUS, wait until the
boiler temperature is displayed, then
switch the control OFF then ON. ECO
will be displayed on the screen.
" will appear on the screen.
" fully to
" will appear on the display.
"

Advertisement