SAFETY INFORMATION
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and
Interruption) power cord that is required by UL. This power supply cord contains
state-of-the-art electronics that sense leakage current. If the cord is damaged and
leakage occurs, power will be disconnected from the unit.
The test and reset buttons on the LCDI Plug are used to check if the plug is
functioning properly.
WARNING: Test LCDI before each use.
To test the plug:
1. Plug power cord into a grounded 3 prong outlet.
2. Press RESET (on some units a green light will turn on).
3. Press the TEST button, the circuit should trip and cut all power to the air
4.
Press the RESET button for use. You will hear a click and the A/C is ready for use.
5.
The power supply cord must be replaced if it fails to trip when the TEST button is
pressed and the unit fails to reset.
NOTES:
• The RESET button must be engaged for proper use.
• Do not use the power supply cord as an ON/OFF switch. The power supply cord
is designed as a protective device.
CAUTION: A damaged power supply cord must be replaced with a new power supply cord.
• The power supply cord contains new user serviceable parts. Opening the
tamper-resistant case voids all warranty and performance claims.
NOTE:
WARNING – RISK OF FIRE
It is important the plug fits tightly into the wall outlet.
If the plug does not fit securely and appears loose, it should not be used.
Have a licensed electrician replace the receptacle.