Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means without the written permission of Technimount System or its affiliate companies.
Contact Information OFFICE ADDRESS Technimount E.M.S. Holding Inc. 3770 Jean Marchand Street, Suite 100-C Quebec (QC) G2C 1Y6 Canada info@technimount.com www.technimount.com T + 1 888.639.2758 F + 1 855.339.6351 NOTE: For any issues with your Technimount product, its components, or for any technical questions during the installation or maintenance, please send an Email to techsupport@technimount.com.
Table of Contents COPYRIGHT ................................2 CONTACT INFORMATION ............................3 Corporate Headquarters ..............................3 INTRODUCTION ..............................6 Purpose of the Document ............................6 Product Description ..............................6 Intended use of the Product ............................6 Possible Mounting Options for the Bracket Pro Serie® 76 ..................7 Symbols and Definitions ...............................8 Warning / Caution / Note .............................9 Product Illustration ..............................10 BRACKET Pro Serie 76 ............................10...
Page 5
Table of Contents Inspection and Maintenance Record .........................34 Training Record ................................35 Replacement Parts ...............................36 WARRANTY ................................37 Warranty Policy ................................37 Return Policy ................................37 Prior to 30 Days ..............................37 Prior to 45 Days ..............................38 Prior to 60 Days ..............................38 Return Authorization ..............................38 Damaged Merchandise ..............................38 International Warranty Clause ..........................38 Claim Process ................................39...
Introduction PURPOSE OF THE DOCUMENT This User Guide is designed to assist you with the installation, operation and maintenance of the Technimount Bracket Pro Serie 76 for the Tempus Pro monitor from Philips. PRODUCT DESCRIPTION The Bracket Pro Serie® 76 mounting system is the only universal solution to mount the Tempus Pro monitor from Philips in different applications such as, on surface, floor, cot/stretcher and wall systems.
Introduction POSSIBLE MOUNTING OPTIONS FOR THE BRACKET PRO SERIE® 76 Safety MD Transporter Safety Arm System Wall Mount System Standard Surface Base (Ground Ambulance in Europe) Return To Table of Contents www.technimount.com BP76 UG 202110-01...
Introduction SYMBOLS AND DEFINITIONS SYMBOL DESCRIPTION Warning and Caution, special attention is required. Consult accompanying documents Safe working load symbol and Load balance symbol Pinch Point Return To Table of Contents BP76 UG 202110-01 www.technimount.com...
Introduction WARNING / CAUTION / NOTE The word warning, caution, or note carry special meaning and should be carefully reviewed. SYMBOL DESCRIPTION Warning Alerts the reader about a situation which, if not avoided, could result in death or serious injury. It may also describe potential serious adverse reactions and safety hazards.
Introduction PRODUCT ILLUSTRATION BRACKET PRO SERIE 76 Front View Made from high-density aluminum with black-anodized finish Main assembly is retained to the Tempus Pro with locking blocks Acetal feet to protect the Standard Bottom Disc and Tempus Pro when placed on the ground Standard Bottom Disc compatible with all of Technimount’s mounting solutions Return To Table of Contents...
Introduction PRODUCT ILLUSTRATION (CONTINUED) BRACKET PRO SERIE 76 (CONTINUED) Back View Main assembly is attached to Technimount molded the Tempus Pro with a quick polyurethane transport handle release and locking mechanism Rubber pads to Anti-Rotation Micro Disc is protect the medical used for vertical support on device from scratches different wall or arm systems...
Introduction SPECIFICATIONS Product Name Bracket Pro Serie® 76 Product Description Dual disc bracket mounting system to secure the Temps® Pro on surfaces, cots/stretchers, floor and walls in emergency vehicles Compatibility of Medical Device* Tempus® Pro Monitor from Philip Environment of Usage EMS (Ground &...
End User/Administrator is responsible to validate regulations and standards for safety in their region, in order to comply with applicable safety regulations. Technimount System is not responsible to inform the End User/Administrator of applicable legislation for safety in their area.
9 It is the responsibility of the operator of the Bracket or any of its options, to ensure equipment being used with the Technimount products meets the installation specifications. Injury may result if non-compatible products are used with Technimount System products. 9 Do not attempt to operate, install or remove the equipment while mobile. Ensure that installation and removal of equipment is done while vehicle or aircraft is immobilized.
Page 15
9 Inspect regularly all components on the equipment for any issue and loose screws, bolts and nuts. 9 Never install the mount into or on other similar mounting systems or brackets without written confirmation by Technimount System as these different systems may be from other brands or models and may not be compatible with Technimount Systems.
NOTE 9 Electrical tools are not recommended, as there is a potential risk of damage to the threads. 9 Technimount System provides screws with Nylon Patch for the installation of the locking assembly block. Return To Table of Contents BP76 UG 202110-01...
Installation Guide INSTALLATION OF THE BRACKET ONTO TEMPUS PRO MONITOR 1. The Bracket Pro Serie® 76 is designed to be installed on the Philips Tempus Pro monitor. 2. To install the Tempus Pro monitor, pull the Red Quick Release Mechanism and raise the top part until it locks into the top position.
Page 18
Installation Guide INSTALLATION OF THE BRACKET ONTO THE TEMPUS PRO MONITOR (CONTINUED) 4. Install the Tempus Pro into the main assembly. 5. Push on the top of the bracket and lower the top part until it locks into the bottom position. 6.
Installation Guide INSTALLATION OF THE BRACKET ONTO TEMPUS PRO MONITOR WITH SMART MOUNT 1. The Bracket Pro Serie® 76 Smart Mount is designed to be installed on the Philips Tempus Pro monitor. 2. To install the Tempus Pro Smart Mount monitor, pull the Red Quick Release Mechanism and raise the top part until it locks into the top position.
Page 20
Installation Guide INSTALLATION OF THE BRACKET ONTO THE TEMPUS PRO MONITOR WITH SMART MOUNT (CONTINUED) 6. Tighten all four screws. 7. Install the Tempus Pro monitor onto the Smart Mount as described in its user guide. 8. Align screw holes. Install both Black Oxide Flat Head Philips Screws, 10-32 X 5/8 in.
Page 21
Installation Guide INSTALLATION OF THE BRACKET ONTO THE TEMPUS PRO MONITOR WITH SMART MOUNT (CONTINUED) 10. Tighten both screws. 11. Install the Tempus Pro monitor onto the Smart Mount as described in its user manual Return To Table of Contents Return To Table of Contents www.technimount.com BP76 UG 202110-01...
Page 22
Installation Guide INSTALLATION OF THE BRACKET ONTO THE TEMPUS PRO MONITOR WITH SMART MOUNT (CONTINUED) 12. Push on the top of the bracket and lower the top part until it locks into the bottom position. 13. The Tempus Pro Smart Mount is ready for EMS transport.
Operation Guide GENERAL OPERATING GUIDELINES FOR THE SAFETY MD TRANSPORTER 9 Use the Safety MD Transporter only as described in the User Guide. 9 Read all the labels and instructions on the product before using the Safety MD Transporter. 9 Always inspect the Micro Base and the Safety MD Transporter for any issue or damage before every use.
Operation Guide OPERATING THE BRACKET ON THE SAFETY MD TRANSPORTER INSTALLING THE BRACKET ONTO THE SAFETY MD TRANSPORTER 1. Only Technimount brackets with an Anti-Rotation Micro Disc on the back can be inserted into the Micro Base located on the Safety MD Transporter. 2.
Operation Guide OPERATING THE BRACKET ON THE SAFETY MD TRANSPORTER (CONTINUED) INSTALLING THE BRACKET ONTO THE SAFETY MD TRANSPORTER (CONTINUED) 4. A Bracket Pro Serie 76 installed on the Safety MD Transporter. ROTATING THE BRACKET ON THE SAFETY MD TRANSPORTER 1.
Operation Guide OPERATING THE BRACKET ON THE SAFETY MD TRANSPORTER (CONTINUED) REMOVING THE BRACKET WITH THE MEDICAL DEVICE FROM THE SAFETY MD TRANSPORTER 1. To remove the bracket from the Safety MD Transporter, press the Red Quick Release Mechanism located on the back Micro Base. 2.
Operation Guide GENERAL OPERATING GUIDELINES FOR THE SAFETY ARM SYSTEM 9 Use the Safety Arm System only as described in its User Guide. 9 Read all the labels and instructions on the product before using the Safety Arm System. 9 Always inspect the Clamp Block, Safety Pin, Lock Pin, and Surface Base before every use.
Operation Guide OPERATING THE BRACKET ON THE SAFETY ARM SYSTEM INSTALLING THE BRACKET ON THE STANDARD BASE 1. Only Technimount brackets with a Standard Bottom Disc can be inserted into the Standard Surface Base located on the Safety Arm System. 2.
Installation Guide OPERATING THE BRACKET ON THE SAFETY ARM SYSTEM (CONTINUED) REMOVING THE BRACKET FROM THE STANDARD SURFACE BASE 1. To remove the bracket from the Safety Arm System, press the Red Quick Release Mechanism located on the front of the Standard Surface Base.
Part Numbers KITS AND OTHER OPTIONS DESCRIPTION PART NUMBER Bracket 320-10-PRO-RDT 553-20-AB-WA Wall Mount 554-20-AB-FL Floor Mount 100-20-UN Standard Surface Base Several Models Available, Safety Arm System refer to Customer Service Different Models Available, Safety MD Transporter refer to Customer Service WARNING Do not modify any components of these system.
Maintenance Guide CLEANING THE BRACKET SYSTEM CLEANING PROCESS WARNING Follow your EMS service's protocol or medical device manufacturer's User Guide for the recommended cleaning procedure of your medical devices. Cleaning procedure below does NOT provide recommendations for cleaning of the medical device.
Maintenance Guide CLEANING THE BRACKET SYSTEM (CONTINUED) CLEANING SOLUTIONS CONTINUED WARNING 9 Some cleaning products are corrosive in nature and may cause damage to the product if used improperly. 9 If the products described are used to clean the equipment, the Bracket and components must be rinsed with clean water and thoroughly dried following cleaning.
Maintenance Guide INSPECTION PROCESS AND SCHEDULE MAINTENANCE PROGRAM The following inspection routine and schedule is intended as a general guide for preventive maintenance of the Bracket. Factors such as weather, environment, geographical location, and individual usage will necessitate different maintenance. If you are unsure as to how to perform these maintenance inspections or at what interval to perform these inspections, please contact your Technical Support Team at techsupport@technimount.com.
Maintenance Guide INSPECTION AND MAINTENANCE RECORD PREVENTIVE MAINTENANCE DATE TIME PERFORMED Return To Table of Contents BP76 UG 202110-01 www.technimount.com...
Maintenance Guide TRAINING RECORD TRAINING DATE TRAINING METHOD USER GUIDE, IN-SERVICE, BASIC TRAINING TRAINEE NAME IN-CLASS, TRAINING UPDATE ETC. Return To Table of Contents www.technimount.com BP76 UG 202110-01...
Maintenance Guide REPLACEMENT PARTS The parts and accessories listed are all currently available for purchase. Some of the parts identified on the assembly drawing parts in this user guide may not be individually available for purchase. Please call Technimount Customer Service : +1.888.639.2758 or at customerservice@technimount.com for availability and pricing.
SET FORTH HEREIN. THERE IS NO WARRANTY OF MERCHANTABILITY AND THERE ARE NO WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE. IN NO EVENT SHALL TECHNIMOUNT SYSTEM BE LIABLE HEREUNDER FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM OR IN ANY MANNER RELATED TO SALES OR USE OF ANY SUCH EQUIPMENT.
▪ Product must be unused, undamaged and in its original packaging ▪ The product return request must be provided in writing and it must be approved by TECHNIMOUNT SYSTEM prior to returning the product ▪ Returns will not be approved on modified or damaged item ▪...
Warranty DAMAGED MERCHANDISE ICC Regulations require that claims for damaged merchandise must be made with the carrier within fifteen (15) days of receiving merchandise. DO NOT ACCEPT DAMAGED SHIPMENTS UNLESS SUCH DAMAGE IS NOTED ON THE DELIVERY RECEIPT AT THE TIME OF RECEIPT. Upon prompt notification, TECHNIMOUNT will file a freight claim with the appropriate carrier for damages incurred.