Table of Contents

Advertisement

Quick Links

BRACKET PRO SERIE
110
®
USER GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for Technimount System Bracket Pro Serie 110

  • Page 1 BRACKET PRO SERIE ® USER GUIDE...
  • Page 2: Copyright

    Copyright Technimount System, Subsidiary of Technologies CGC Inc. 2019. All Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means without the written permission of Technimount System or its affiliate companies. Trademark Attributions Bracket Pro Serie®...
  • Page 3: Contact Information

    Contact Information CORPORATE HEADQUARTERS Technimount System Customer Service or Technical Support 3770 Jean Marchand Street, Suite 100 Quebec (QC) G2C 1Y6 Canada www.technimount.com T + 1 581.998.9820 F + 1 855.339.6351 customerservice@technimount.com techsupport@technimount.com NOTE: Please have the serial number of your Technimount product available (as shown in the figure below) when calling Technimount Customer Service or Technical Support.
  • Page 4: Table Of Contents

    Table of Contents COPYRIGHT ................................2 CONTACT INFORMATION ............................3 INTRODUCTION ..............................6 Product Description ..............................6 Intended use of the Product ............................6 Possible Mounting Options for the Bracket Pro Serie® 110 ..................7 Symbols and Definitions ...............................8 Warning / Caution / Note .............................9 Product Illustration ..............................10 BRACKET Pro Serie®...
  • Page 5 Table of Contents Warranty Policy ................................36 Warranty Options ...............................37 three Warranty Options for Technimount Products ..................37 International Warranty Clause ..........................37 RETURN POLICY ..............................38 Return of Merchandise ..............................38 Prior to 30 Days ..............................38 Prior to 45 Days ..............................38 Prior to 60 Days ..............................38 Return Merchandise Authorization ........................38 Damaged Merchandise ............................38 SAE CERTIFICATION .............................
  • Page 6: Introduction

    Introduction This User Guide is designed to assist you with the installation, operation and maintenance of the Technimount Bracket Pro Serie 110 for the Monnal T-60 Ventilator. Please read this User Guide thoroughly before using this equipment. To ensure the safe operation of this equipment, it is recommended to train staff prior to use. PRODUCT DESCRIPTION The Bracket Pro Serie®...
  • Page 7: Possible Mounting Options For The Bracket Pro Serie® 110

    Introduction POSSIBLE MOUNTING OPTIONS FOR THE BRACKET PRO SERIE® 110 Safety MD Transporter Wall Mount System (Ground Ambulance in Europe) Technimount Air Ambulance Stretcher Safety Floor Mount Arm System Technimount Universal Standard Base Return To Table of Contents www.technimount.com BP110 UG 202002-R01...
  • Page 8: Symbols And Definitions

    Introduction SYMBOLS AND DEFINITIONS SYMBOL DESCRIPTION Caution, special attention is required. Consult accompanying documents Safe working load symbol Pinch Point Load balance symbol Return To Table of Contents BP110 UG 202002-R01 www.technimount.com...
  • Page 9: Warning / Caution / Note

    Introduction WARNING / CAUTION / NOTE The word warning, caution, or note carry special meaning and should be carefully reviewed. SYMBOL DESCRIPTION Warning Alerts the reader about a situation which, if not avoided, could result in death or serious injury. It may also describe potential serious adverse reactions and safety hazards.
  • Page 10: Product Illustration

    Introduction PRODUCT ILLUSTRATION BRACKET PRO SERIE® 110 Front View Retractable Back Hooks for Back Plate (#2) Temporary Transfer is Installed after Between Hospital the Junction and Ambulance Plate and goes Under the Device Handle High-Density Junction Plate (#1) Aluminum is Installed First with Silver- onto the Monnal Anodized Finish...
  • Page 11: Back View

    Introduction PRODUCT ILLUSTRATION (CONTINUED) BRACKET PRO SERIE ® 110 (CONTINUED) Retractable Back Hooks for Back View Temporary Transfer Between Hospital and Ambulance Back Plate (#2) is Installed after the Junction Plate and goes Under the Device Handle Junction Plate (#1) is Installed First onto the Monnal T60 Back Side...
  • Page 12 Introduction Product Name Bracket Pro Serie® 110 Monnal T60 Ventilator from Air Liquide Compatibility of Medical Device EMS (Ground & Flight) – Hospital/Clinic, Military Environment of Usage High-Density Aluminum with Gray Anodized Finish – Acetal Feet Device Section Material Aluminum with Stainless Steel Insert and Peek Cushions Bottom Disc Section Material High-Density Aluminum with Gray-Anodized Finish Anti-Rotation Back Disc Material...
  • Page 13: Notice

    Technimount hereby declares that the Bracket Pro Serie® 110 Mounting System is in compliance with the essential requirements and other relevant provisions of the Directive 1999/5/EC and SAE J3043. A copy of the original declaration of conformity can be obtained by contacting Technimount System’s Regulatory Affairs Department: Technimount System C/O: Regulatory Affairs info@technimount.com...
  • Page 14: Summary Of Safety Precautions

    9 It is the responsibility of the operator of the Bracket or any of its options, to ensure equipment being used with the Technimount products meets the installation specifications. Injury may result if non-compatible products are used with Technimount System products. 9 Do not attempt to operate, install or remove the equipment while mobile. Ensure that installation and removal of equipment is done while vehicle or aircraft is immobilized.
  • Page 15 9 Inspect regularly all components on the equipment for any issue and loose screws, bolts and nuts. 9 Never install the mount into or on other similar mounting systems or brackets without written confirmation by Technimount System as these different systems may be from other brands or models and may not be compatible with Technimount Systems.
  • Page 16: Installation Guide

    NOTE 9 Electrical tools are not recommended, as there is a potential risk of damage to the threads. 9 Technimount System provides screws with scotchgrip for the installation of the Back Plates and main assembly. FIGURE 1. 4 WASHERS AND FIGURE 2. 6 HEXAGONAL...
  • Page 17 Installation Guide INSTALLATION OF THE BRACKET ONTO THE MONNAL VENTILATOR 1. The Bracket Pro Serie® 110 is designed to be installed on the Monnal T60 ventilator including its bag. WARNING 9 This particluar version of the bracket cannot be used without the bag. 2.
  • Page 18 Installation Guide INSTALLATION OF THE BRACKET ONTO THE MONNAL VENTILATOR (CONTINUED) 6. Locate the 4 screws on the back metal plate. 7. Remove the back plate with hooks by removing all 4 screws. 8. Remove the metal plate with hooks completely 9.
  • Page 19 Installation Guide INSTALLATION OF THE BRACKET ONTO THE MONNAL VENTILATOR (CONTINUED) Show same view with fluid pole 11. Start by placing the Junction Plate first onto the the Back of the Monnal T60 ventilaor. 12. Lift the top handle of the ventilator. 13.
  • Page 20 Installation Guide INSTALLATION OF THE BRACKET ONTO THE MONNAL VENTILATOR (CONTINUED) 17. Replace the bag back onto the Monnal T60 ventilator with back plates installed. 18. The device is now ready to be installed onto the main assembly. 19. There are 3 screws to be installed on each side of the back plates onto the main assembly.
  • Page 21: Using The Back Hooks

    Installation Guide INSTALLATION OF THE BRACKET ONTO THE MONNAL VENTILATOR (CONTINUED) 22. The unit is now ready for EMS transport. CAUTION 9 Always Technimount Brackets with compatible and approved mounting systems and products by Technimount. USING THE BACK HOOKS 1. To open the hooks, open one hook at a time by pulling the hook towards you.
  • Page 22: Operation Guide

    Operation Guide GENERAL OPERATING GUIDELINES FOR THE SAFETY MD TRANSPORTER 9 Use the Safety MD Transporter only as described in the User Guide. 9 Read all the labels and instructions on the product before using the Safety MD Transporter. 9 Always inspect the Micro Base and the Safety MD Transporter for any issue or damage before every use.
  • Page 23: Operating The Bracket On The Safety Md Transporter

    Operation Guide OPERATING THE BRACKET ON THE SAFETY MD TRANSPORTER INSTALLING THE BRACKET ONTO THE SAFETY MD TRANSPORTER 1. Only Technimount brackets with an anti-rotation micro disc on the back can be inserted into the Micro Base located on the Safety MD Transporter. 2.
  • Page 24: Rotating The Bracket On The Safety Md Transporter

    Operation Guide OPERATING THE BRACKET ON THE SAFETY MD TRANSPORTER (CONTINUED) INSTALLING THE BRACKET ONTO THE SAFETY MD TRANSPORTER (CONTINUED) 4. A Bracket Pro Serie 110 installed on the Safety MD Transporter. ROTATING THE BRACKET ON THE SAFETY MD TRANSPORTER 1.
  • Page 25: Removing The Bracket With The Medical Device From The Safety Md Transporter

    Operation Guide OPERATING THE BRACKET ON THE SAFETY MD TRANSPORTER (CONTINUED) REMOVING THE BRACKET WITH THE MEDICAL DEVICE FROM THE SAFETY MD TRANSPORTER 1. To remove the bracket from the Safety MD Transporter, press the red quick release button located on the back Micro Base. 2.
  • Page 26: General Operating Guidelines For The Safety Arm System

    Operation Guide GENERAL OPERATING GUIDELINES FOR THE SAFETY ARM SYSTEM 9 Use the Safety Arm System only as described in its User Guide. 9 Read all the labels and instructions on the product before using the Safety Arm System. 9 Always inspect the Clamp Block, Safety Pin, Lock Pin, and Surface Base before every use.
  • Page 27: Operating The Bracket On The Safety Arm System

    Operation Guide OPERATING THE BRACKET ON THE SAFETY ARM SYSTEM INSTALLING THE BRACKET ON THE STANDARD BASE 1. Only Technimount brackets with an standard bottom disc can be inserted into the surface Base located on the Safety Arm. 2. To insert the bracket into the standard surface base, slide into the base horizontally from the front of the base.
  • Page 28: Removing The Bracket From The Standard Surface Base

    Installation Guide OPERATING THE BRACKET ON THE SAFETY ARM SYSTEM (CONTINUED) REMOVING THE BRACKET FROM THE STANDARD SURFACE BASE 1. To remove the bracket from the Safety MD Transporter, press the red quick release button located on the back Standard Base. 2.
  • Page 29: Part Numbers

    Part Numbers KITS AND OTHER OPTIONS DESCRIPTION PART NUMBER Bracket Only 552-10-AB-BR 553-20-AB-WA Wall Mount Only 554-20-AB-FL Floor Mount Only 100-20-UN Unviersal Standard Base Several Models Available, Safety Arm System refer to Customer Service Different Models Available, Safety MD Transporter refer to Customer Service WARNING Do not modify any components of these system.
  • Page 30: Maintenance Guide

    Maintenance Guide CLEANING THE BRACKET SYSTEM CLEANING PROCESS The Bracket can be cleaned by using a pressure washer. The bracket may show some signs of oxidation or discoloration from continuous washing, however, degradation of the cot/stretcher’s performance or functionality will not be affected due to power washing if cleaning instructions are properly followed.
  • Page 31: Removal Of Iodine Compounds

    Maintenance Guide CLEANING THE BRACKET SYSTEM (CONTINUED) CLEANING SOLUTIONS CONTINUED WARNING 9 Some cleaning products are corrosive in nature and may cause damage to the product if used improperly. 9 If the products described are used to clean the equipment, the Bracket and components must be rinsed with clean water and thoroughly dried following cleaning.
  • Page 32: Inspection Process And Schedule

    Maintenance Guide INSPECTION PROCESS AND SCHEDULE MAINTENANCE PROGRAM The following inspection routine and schedule is intended as a general guide for preventive maintenance of the Bracket. Factors such as weather, environment, geographical location, and individual usage will necessitate different maintenance. If you are unsure as to how to perform these maintenance inspections or at what interval to perform these inspections, please contact your Technical Support Team at techsupport@technimount.com.
  • Page 33: Inspection And Maintenance Record

    Maintenance Guide INSPECTION AND MAINTENANCE RECORD PREVENTIVE MAINTENANCE DATE TIME PERFORMED Return To Table of Contents www.technimount.com BP110 UG 202002-R01...
  • Page 34: Training Record

    Maintenance Guide TRAINING RECORD TRAINING DATE TRAINING METHOD USER GUIDE, IN-SERVICE, BASIC TRAINING TRAINEE NAME IN-CLASS, TRAINING UPDATE ETC. Return To Table of Contents BP110 UG 202002-R01 www.technimount.com...
  • Page 35: Replacement Parts

    Maintenance Guide REPLACEMENT PARTS The parts and accessories listed are all currently available for purchase. Some of the parts identified on the assembly drawing parts in this user guide may not be individually available for purchase. Please call Technimount Customer Service or Technical Support : +1.581-998-9820 or at customerservice@technimount.com techsupport@...
  • Page 36: Warranty

    LIMITED RESPONSIBILITY AND WARRANTY Technimount System shall not be responsible for damage to the part or products resulting from improper installation or use, abuse, neglect, accident, servicing or any modification to any part of a Technimount product by anyone other than Technimount System or an organization certified by Technimount.
  • Page 37: Warranty Options

    Warranty WARRANTY OPTIONS THREE WARRANTY OPTIONS FOR TECHNIMOUNT PRODUCTS 1. One-year (1) additional warranty after the original warranty has expired for parts and labor has terminated. Technimount guaranties to the original purchaser that its products should be free from manufacturing nonconformities that affect product performance and customer satisfaction for a period of one (1) year following the end date of the original warranty.
  • Page 38: Return Policy

    Return Policy RETURN OF MERCHANDISE The parts and/or components may be returned up to 60 days of receiving the product(s) if they meet the following guidelines: PRIOR TO 30 DAYS 9 30-day money back guarantee in effect 9 Technimount is responsible for all charges 9 Returns will not be approved on modified item PRIOR TO 45 DAYS 9 Product must be unused, undamaged and in the original packaging...
  • Page 39: Sae Certification

    SAE Certification Return To Table of Contents www.technimount.com BP110 UG 202002-R01...
  • Page 40 Technimount System - Brand of Technologies CGC Corporate Headquarters 3770 Jean Marchand Street, Suite 100 Quebec (QC) G2C 1Y6 Canada T + 1 581.998.9820 F + 1 855.339.6351 technimount.com info@technimount.com © Copyright 2020 Technimount System All Rights Reserved Printed in Canada...

Table of Contents