Advertisement

Quick Links

P350-M0_062015
Hand Pump
Instruction Manual
MODELS: P350, P601S, P1000, P1000AD & P2001
SFA Companies
10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419
*
Fax: 816-448-2142
E-mail: sales@bvahydraulics.com
Website: www.bvahydraulics.com
Maximum Operating Pressure 10,000 PSI
Models P350
Model P601S
Model P1000 &P1000AD
Model P2001
!
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
Printed in Taiwan

Advertisement

Table of Contents
loading

Summary of Contents for BVA P601S

  • Page 1 P350-M0_062015 Hand Pump Instruction Manual MODELS: P350, P601S, P1000, P1000AD & P2001 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com Maximum Operating Pressure 10,000 PSI Models P350 Model P601S Model P1000 &P1000AD Model P2001 This is the safety alert symbol.
  • Page 2: Safety And General Information

    WARNING: Model P601S is operated with a non-vented reservoir. If the reservoir is subjected to high pressure, the casing may rupture. Never attempt to return more oil to the reservoir than it is capable of holding Oil Outlet Port 3/8”...
  • Page 3: Specifications

    Distance (in) stage stage stage stage P350 21.3 0.18 0.05 2.56 14.1 x 3.4 x 5.9 speed Single P601S 36.5 0.15 3.74 20.8 x 5.2 x 6.5 13.0 Single speed 10,000 Acting P1000 61.0 3.94 20 x 4.9 x 6.3 13.7...
  • Page 4: Operation

    CAUTION: NEVER operate pump with release valve closed and safety purpose. and disconnected from application. If operated in this NOTICE: It is recommended to use BVA fittings, gauge adapter condition, the hose and connections become pressurized. and guage. This increases burst hazard. Damage may occur to pump and its components 4.
  • Page 5: Maintenance

    4. Shield pump with a protective cover. TROUBLESHOOTING GUIDE The following information is intended as an aid in determining if problem exists. Pumps should be repaired only by authorized BVA Service Center. For repair service, contact service center in your area.
  • Page 6 Note: Not all components of the pump are replacement items, but are illustrated as a convenient reference of location and position in the assembly sequence. Parts Illustration 26-1 26-2 26-3 26-4 26-5 Note: To ensure safe and reliable performance, replace worn or damaged parts with BVA Hydraulics Authorized Replacement Parts only.
  • Page 7 (*) - Indicates items included in, and available only as part of Seal Kit. Seal Kits require special skill, training and equipment to repair. Installation must be done by Authorized Service Center. Contact BVA for list of Authorized Service Centers.
  • Page 8 Note: Not all components of the pump are replacement items, but are illustrated as a convenient reference of location and position in the assembly sequence. Parts Illustration Note: To ensure safe and reliable performance, replace worn or damaged parts with BVA Hydraulics Authorized Replacement Parts only.
  • Page 9 (*) - Indicates items included in, and available only as part of Seal Kit. Seal Kits require special skill, training and equipment to repair. Installation must be done by Authorized Service Center. Contact BVA for list of Authorized Service Centers.
  • Page 10 Note: Not all components of the pump are replacement items, but are illustrated as a convenient reference of location and position in the assembly sequence. Parts Illustration Note: To ensure safe and reliable performance, replace worn or damaged parts with BVA Hydraulics Authorized Replacement Parts only.
  • Page 11 (*) - Indicates items included in, and available only as part of Seal Kit. Seal Kits require special skill, training and equipment to repair. Installation must be done by Authorized Service Center. Contact BVA for list of Authorized Service Centers.
  • Page 12 Note: Not all components of the pump are replacement items, but are illustrated as a convenient reference of location and position in the assembly sequence. Parts Illustration Note: To ensure safe and reliable performance, replace worn or damaged parts with BVA Hydraulics Authorized Replacement Parts only.
  • Page 13 (*) - Indicates items included in, and available only as part of Seal Kit. Seal Kits require special skill, training and equipment to repair. Installation must be done by Authorized Service Center. Contact BVA for list of Authorized Service Centers.
  • Page 14 Note: Not all components of the pump are replacement items, but are illustrated as a convenient reference of location and position in the assembly sequence. Parts Illustration Note: To ensure safe and reliable performance, replace worn or damaged parts with BVA Hydraulics Authorized Replacement Parts only.
  • Page 15 (*) - Indicates items included in, and available only as part of Seal Kit. Seal Kits require special skill, training and equipment to repair. Installation must be done by Authorized Service Center. Contact BVA for list of Authorized Service Centers.
  • Page 16: Limited Lifetime Warranty

    This warranty does not cover ordinary wear and tear, overloading, alterations (including repairs or attempted repairs not performed by BVA Hydraulics or one of its authorized personnel), improper fluid use, or use of the product in any manner for which the product was not intended or the use of which is not in accordance with the instructions or warnings provided with the product.