Hearth & Home OXDV30SP Installation And Operating Instructions Manual

Hearth & Home OXDV30SP Installation And Operating Instructions Manual

Direct/natural vent gas stove
Hide thumbs Also See for OXDV30SP:
Table of Contents

Advertisement

Quick Links

S
AFETY
DANGER
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall
be installed for the protection of children and
other at risk individuals.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
11
Hearth and Home Technolgies • Oxford Direct/Natural Vent Installation Manual_R15 • 08/18
Direct/Natural Vent Gas Stove
Installation and Operating Instructions
Models: OXDV30SP
CERTIFIED
B
ARRIER
5123
Oxford cover
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death or property damage.
• Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
• WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use
any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
– If you cannot reach your gas supplier, call the
fire department.
• Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional
information consult a qualified installer, service
agency or the gas supplier.
This appliance is for use only with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
20306543
This appliance may be installed in an aftermarket,*
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes.
* Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
!
WARNING
!
WARNING
3-90-693831

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OXDV30SP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hearth & Home OXDV30SP

  • Page 1 Direct/Natural Vent Gas Stove Installation and Operating Instructions Models: OXDV30SP WARNING CERTIFIED AFETY ARRIER FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of an Hearth & Home Technologies stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Table of Contents Installation Operation General Information .
  • Page 3: General Information

    WARNING: Operation of this heater when not connected to a properly installed and maintained venting system The Oxford Direct Vent, Model No. OXDV30SP, is a vented can result in carbon monoxide (CO) poisoning and gas appliance listed to the ANSI standard Z21.88-2014 and possible death.
  • Page 4: Requirements For The Commonwealth Of Massachusetts

    Requirements for the Commonwealth of Massachusetts California Safety Information All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber. WARNING For all side wall horizontally vented gas fueled equipment This product and the fuels used to operate this product installed in every dwelling, building or structure used in whole (liquid propane or natural gas), and the products of or in part for residential purposes, including those owned or...
  • Page 5: Oxford Dimensions

    Oxford Direct Vent / Natural Vent Dimensions Refer to Figures 3 & 4 for Flue Collar Centerline Dimensions 6³⁄₄" (172mm) Valve Inlet 24¹⁄₂" (622mm) 28³⁄₈" (721mm) C L Valve 4³⁄₈" Inlet (111mm) 12¹⁄₂" 23" (318mm) (584mm) 17" (419mm) Figure 1 - Oxford dimensions. 5123 Attention Oxford dims...
  • Page 6: Unpack Stove

    Installation: Direct Vent System Only Unpack the Stove Using a 1/2" wrench, remove (4) lag bolts installed through the shipping brackets and into the skid. Using a 7/16" wrench, remove (2) 1/4-20 x 1/2” bolts holding the bracket onto the legs.
  • Page 7: Parallel Installation

    Parallel Installation: Wall Centerline from Floor Minimum Clearance and Flue Centerline Direct Vent and Natural Vent Stove Clearances 4" (102 mm) Effective Minimum (A) 4" (102 mm) Wall Thimble 57-1/2" (1461 mm) (HHT Pipe) Pipe Centerlines 15-1/2" (395 mm) ST128b ST1121 Centerline 53-1/2"...
  • Page 8: Gas Specifications

    Horizontal Termination - Direct Vent ONLY Gas Specifications The vent must rise vertically a minimum of 24” (610 mm) off Max. Min. the top of the unit, before the first elbow. The horizontal run Input Input may extend up to 20’ (6 m) and include a vertical rise of up Model Fuel Control...
  • Page 9: Vertical Termination - Direct Vent Only

    Vertical Termination - Direct Vent ONLY Vent Termination Clearances A vertical vent system must terminate no less than 8' (2.44 When planning the installation, consider the location of the m) and no more than 40' (12 m) above the appliance flue vent terminal and clearances. Some of the most common collar.
  • Page 10 Venting Termination Clearances Your stove is approved to be vented either through the side wall, or vertical through the roof. • This unit does not require any opening for inspection of vent pipe. • Only HHT and Duravent venting components specifically approved and labeled for this stove may be used.
  • Page 11: General Venting Information - Termination Location

    General Venting Information - Termination Location INSIDE CORNER DETAIL Fixed Closed Fixed Operable Closed CFM145a VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installation US Installations CFM145a Clearance above grade, verenda, porch, deck or DV Termin Location 12" (30cm) 12" (30cm) balcony 5/01/01 Rev.
  • Page 12: Termination Clearances

    Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony - Balcony - with no side wall with perpendicular side wall = Min.
  • Page 13: Approved Vent System Components

    Approved Vent System Components DuraVent Components The heater must be vented to the outdoors through an Starter Pipe Assembly (incl. inner & outer 46DVA-ADP sections) adjacent exterior wall or through the roof. The venting system must be comprised of the appropriate listed venting 90°...
  • Page 14: Install The Optional Fan

    • Install the Optional Fan Remove retaining nut from shaft of rheostat. (if If you are installing the optional convection Fan Kit #2767 preinstalled) (FK26), continue here. If you are not installing a Fan Kit, go • Insert the rheostat through the hole in the back of the left to "Venting System Assembly".
  • Page 15: Venting System Assembly - Direct Vent

    Venting System Assembly - Direct Vent 5. Install the Outer Adapter Pipe: Apply a 1/4” bead of cement around the inside wall of the pipe, about 1” from For U.S. installations: The venting system must conform the end. Insert the pipe over the stove flue collar, keeping with local codes and/or the current National Fuel Gas Code, the vertical seam oriented to the back of the stove.
  • Page 16: Install Vent Adapter Pipe (Dura-Vent Components)

    Install the Vent Adapter Pipe Side Wall Termination Assembly (Simpson Dura-Vent Components) 1. Locate the vent opening on the wall. Refer to Figure 5, to determine the opening centerline. It may be necessary 1. Install the Restrictor Plate: Consult Figure 8 to to first position the stove and measure to find the hole determine whether the restrictor plate is needed.
  • Page 17 For DuraVent pipe only: Install vent pipe by aligning the locking system together, sliding the pipes together and twisting clockwise. • Install 90° elbow. Twist lock as before. • Slide the wall plate over horizontal run before attaching the horizontal run to the elbow. Fasten wall plate to wall.
  • Page 18: Vent Termination Below Grade

    Vent Termination Below Grade Install Snorkel Kit when it is not possible to meet the required Recessed Wall vent termination clearances of 12” (305 mm) above grade level. The snorkel kit will allow installation depth of down Firestop to 7” (178 mm) below grade level. The seven inches is Finishing measured from the center of the horizontal vent pipe as Collar...
  • Page 19: Venting System Assembly - Natural Vent

    8. Install appropriate pipe sections until the vent run Venting System Assembly - Natural Vent reaches above the flashing. The enlarged ends of the General Information vent sections always face downward. The heater is shipped from the factory as a Direct Vent 9. Install the storm collar and seal around the joints. Heater.
  • Page 20: Install The Log Set

    Attach the first section of venting to the draft hood. Depending on the length of the individual venting sections Left Log Right Log and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones.
  • Page 21: Burner Information

    In the U.S.; Gas connection should be made in accordance To adjust the air shutter, the following procedures should be with current National Fuel Gas Code, ANSI Z223.1/NFPA followed: 54. Since some municipalities have additional local codes, 1. Remove barrier screen first by pulling out and up. be sure to consult your local authority.
  • Page 22: Complete The Assembly

    The shutter may be adjusted between the factory adjusted Left Burner Leg 1/2” to fully open. Reassemble the shutter to allow the rear injector air inlet to close from the minimum 1/2” opening to fully open. (Figure 39) You may have to try more than Injector Shoulder once to find the correct air shutter opening for best results depending on your altitude.
  • Page 23: Thermostat Connection (Optional)

    Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation. Thermostat Wire / Gauge Maximum Run 3/8” Locking Nut 20 Feet 20-40 Feet up to 60 Feet...
  • Page 24: Safety Barrier Installation

    DANGER CERTIFIED AFETY ARRIER HOT GLASS WILL CAUSE BURNS. Safety Barrier Installation Instructions DO NOT TOUCH GLASS UNTIL COOLED. NOTE: A barrier designed to reduce the risk of burns from NEVER ALLOW CHILDREN the hot viewing glass is provided with this appliance and TO TOUCH GLASS.
  • Page 25: Operation

    Operation Flame & Temperature Adjustment For stoves equipped with HI/LO valves, flame adjustment Your First Fire is accomplished by rotating the HI/LO adjustment knob Read these instructions carefully and familiarize yourself located near the center of the gas control valve. (Figure 47) with the burner controls.
  • Page 26: Lighting And Operating Instructions

    Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • A. This heater has a pilot which must be lit manually. When If you cannot reach your gas supplier, call the lighting the pilot follow these instructions exactly.
  • Page 27: Troubleshooting - Sit Nova 820 Gas Control System

    Troubleshooting the Gas Control System SIT NOVA 820 MILLIVOLT VALVE NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. Symptom Possible Cause Corrective Action 1. Spark ignitor will not light A. Defective or misaligned electrode at Using a match, light pilot.
  • Page 28: Fuel Conversion Instructions

    Fuel Conversion Instructions Remove Screws Rear Log Bracket WARNING! This conversion kit shall be installed by Pilot a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of...
  • Page 29: Pilot Type 1

    Pilot Orifice Conversion 1. Locate pilot. (Figure 50) 2. Replace pilot orifice. Pilot Pilot Type 1 • Remove pilot hood by lifting up. (Figure 53) Do not remove snap ring to remove pilot hood. NOTE: It is not necessary to remove the pilot tube for conversion. Index Marks •...
  • Page 30: Injector Orifice Size

     Table 2 - Injector Orifice Size Matrix Conversion to Natural Gas Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maximum 30005155 #54 / .055" 20000130 #44 / .086" 30000334 19,000 28,000 Conversion to LP (Propane) Input (BTU/h) Kit # Front Part # Rear Part # Minimum...
  • Page 31: Glass Replacement

    Glass Replacement Inspect the Vent System Annually Replace glass only with Hearth & Home Technologies Have the vent system inspected annually by a qualified approved parts. Refer to the "Replacement Parts" section technician. Shut off the main gas supply before inspecting of this manual.
  • Page 32: Wiring Diagram

    Wiring Diagrams POWER On/Off Switch Wiring CORD Chassis TP/TH Ground Millivolt Gas Valve Black Optional Thermostat Wiring Thermostat Thermostat FAN JUNCTION BOX (Optional) (Optional) Strain Relief St124b TP/TH on/off/switch ON / OFF Rheostat Millivolt wiring Gas Valve 1/11/00 djt Black Snapstat Figure 62 - On/Off switch and optional thermostat circuit.
  • Page 33: Service Parts List

    Service Parts List OXDV30SP Service Parts Oxford Direct Vent Gas Stove Beginning Manufacturing Date:June 2017 With Screen Barrier Ending Manufacturing Date: Active 15 17 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Stocked Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 34 OXDV30SP Service Parts Beginning Manufacturing Date:June 2017 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Stocked Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 35: Optional Accessories

    OXDV30SP Service Parts Beginning Manufacturing Date:June 2017 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Stocked Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 36: Warranty

    Optional Accessories Remote Controls The remote control allows you to turn the heater on or off Fan Kits from anywhere in the room. FK26 Fan Model Functions Controlled The FK26 fan helps distribute heated air from within the Push Button, ON/OFF firebox out into the room.
  • Page 37 Hearth & Home Technologies LIMITED LIFETIME WARRANTY Hearth & Home Technologies, on behalf of its hearth brands (“HHT”), extends the following warranty for HHT gas, wood, pellet and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture.
  • Page 38 WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. •...
  • Page 39 This warranty is void if: • The appliance has been over-fired, operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, deformation/warping of interior cast iron structure or components, rust colored cast iron, bubbling, cracking and discoloration of steel or enamel finishes.
  • Page 40: Efficiencies

    Efficiency Ratings EnerGuide Ratings D.O.E Model Fireplace Efficiency (%) (AFUE%) OXDV30SP 58.4 Based on CSA P.4.1-2015 352 Mountain House Road Halifax, PA 17032...

Table of Contents