Serial Console Redirection - Acer Altos R700 Service Manual

Hide thumbs Also See for Altos R700:
Table of Contents

Advertisement

Serial Console Redirection

Feature
BIOS
Disabled
Redirection Port
Serial 1 (DB-9)
Serial 2 (RJ45)
ACPI
Disabled
Redirection Port
Serial 1 (DB-9)
Serial 2(RJ45)
BIOS
9600
Redirection
19.2K
Baud Rate
57.6K
115.2K
BIOS
No Flow Control
Redirection
CTS/RTS
Flow Control
XON/XOFF
CTS/RTS+CD
Chapter 2
Option
Selects the Serial port to use for BIOS Console
Redirection. "Disabled" completely disables BIOS
Console Redirection.
Selects the Serial port to use for ACPI Headless
Console Redirection. "Disabled" completely
disables ACPI Headless Console Redirection.
When console redirection is enabled, use the baud
rate specified. When the Emergency Management
Port shares the COM port as console redirection, the
baud rate must be set to 19.2K to match the
Emergency Management Port baud rate, unless
auto-baud feature is used. BMC/IPMI may override
this value.
NoFlow Control = No flow control
CTS/RTS=Hardware base flow control
XON/XOFF= Software flow control
CTS/RTS+CD= Hardware based+Carrier Detect flow
control must be set to CTS/RTS or CTS/RTS+CD
depending on whether a modem is used.
Description
46

Advertisement

Table of Contents
loading

Table of Contents