Server - Acer Altos R700 Service Manual

Hide thumbs Also See for Altos R700:
Table of Contents

Advertisement

Server

Feature
System Management
Console Redirection
Event Log Configuration
Assert NMI on PERR
Assert NMI on SERR
FRB-2 Policy
POST Error Pause
Platform Event Filtering
43
Option
N/A
N/A
N/A
Disabled
Enabled
Enabled
Disabled
Disable BSP
Do Not Disable BSP
Retry 3 Times
Disable FRB2 Timer
Enabled
Disabled
Disabled
Enabled
Description
Selects sub-menu
Selects sub-menu
Selects sub-menu
If enabled, PCI bus parity error (PERR) is
enabled and is routed to NMI.
If enabled, PCI bus system error (SERR) is
enabled and is routed to NMI.
Controls the policy of the FRB-2 timeout.
This option determines when the Boot
Strap Processor (BSP) should be disabled
if FRB-2 error occur.
If enabled, the system will wait for user
intervention on critical POST errors. If
disabled, the system will boot with no
intervention, if possible.
Enable/Disable triggers for system sensor
events inside the BMC.