CHAPTER 4 SERVICE MODE
G. Specification Settings Mode [5]
•
To activate specification settings mode, press [5] on the keypad and then the AE key.
•
To select an item, press the appropriate key on the keypad and then the Start key.
•
To change the setting, press the appropriate keys on the keypad and then the AE key.
•
To clear an item, press the Clear key.
•
A press on the Start key executes the respective operation.
No.
501
Characteristics storage for
multifeeder paper width sensor
502
Copy density notation switching
(9/17 steps)
503
Auto power-off cancel
504
Copy count upper limit
505
Universal cassette paper size
506
Separation static eliminator output
voltage switching
507
Fixing forced wait
508
Fixing control temperature
switching
4-14
Description
See p. 2-39.
9 steps: 0
17 steps:
1
default: 0 (9 steps)
• When '1' is entered on the keypad, the
notation will be 'ON', activating the auto
power-off function.
• When '0' is entered on the keypad, the
notation will be 'OFF', de-activating the auto
power-off function.
default: on.
The auto power-off period is set in user mode;
since the copier's WAIT time is 0, it is best to
keep the auto power-off mechanism to be
enabled.
settings: 0 to 99
default: 0
When set to '0', the upper limit will be 100
copies.
See p. 2-40.
settings: 0 to 14
default: 0
002:
2.5 kV
004:
4 kV
default: 0
When activated, the period of initial rotation is
increased; activate it if the fixing on the first copy
is poor because of low temperature conditions.
0: disabled
1: enabled
default: 0
001:
225°C
002:
215°C
003:
200°C
default: 002
Table 4-9
Remarks
See p. 2-28.