F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER

SPECIFICATIONS

IMPORTANT
The specifications given in this publication do not
include normal manufacturing tolerances. Therefore,
this unit may not exactly match the listed
specifications. This product is tested and calibrated
under closely controlled conditions, and some minor
differences in performance can be expected if those
conditions are changed.
Models:
The F116 (Series 16000) air cleaner is available in two
cabinet sizes. The shorter cabinet uses a prefilter with one
primary filter while the longer cabinet uses a prefilter with two
primary filters. Refer to Table 1 for model descriptions.
Construction:
.0508 in., 16 GA unpainted aluminum
Model
Voltage
F116A1021
120 Vac, 60
(16002)
Hz, 1PHS, 0.4A
F116A1047
120 Vac, 60
(16004)
Hz, 1PHS, 0.4A
F116A1120
120 Vac, 60
(16012)
Hz, 1PHS, 0.4A
F116E1001
120 Vac, 60
(16000)
Hz, 1PHS, 0.4A
F116E1100
120 Vac, 60
(16010)
Hz, 1PHS, 0.4A
a
Primary filters must be ordered separately. The choices include a 95% D.O.P. filter, ASHRAE dust spot filter or
two sorbent modules.
b
Second primary filter must be ordered separately. The choices include a 95 % D.O.P. filter, ASHRAE dust spot filter or
two sorbent modules.

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1.
Your local Honeywell/Environcaire® Commercial Air Cleaner Distributor (check white pages of your phone directory).
Home and Building Control Customer Relations
2.
Commercial Air Products
Honeywell, 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0200
Table 1. F116 (Series 16000) Description.
Filtering
Stages
Contains
Two
1 prefilter and
1 HEPA filter
Two
1 prefilter
Three
1 prefilter
Two
1 prefilter and
2 electrostatic precipitator
collecting cells
Three
1 prefilter and
2 electrostatic precipitator
collecting cells
Blower/Motor:
• three speed direct drive forward curve
• 1070 RPM nominal speed
• thermal circuit breaker
NOTE: Oil annually.
Electrostatic Precipitator Power Supply:
• regulated solid state
• 0.4A at 120V
• high voltage indicator light
• pressure switch activated (no air flow,
no power supply voltage)
• cell performance indicator
• arcing control circuitry
Static Pressure:
Minimum: 1.2" W.G.
Maximum: 1.85" W.G.
Suggested Applications
Medical isolation wards, industrial clean rooms
and source capture of highly toxic particulates
a
Any airborne particulate or gas/odor/VOC, but
not in combination
a
Any particulate and/or gas/odor/VOC
Any nonconductive airborne respirable
particulate such as tobacco smoke, atmospheric
dusts, brazing smoke and some oil smokes
Any respirable particulate and gas/odor/VOC
b
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

F116F116a1021F116a1047F116a11201600216004 ... Show all

Table of Contents