MedTrack Rehabilitation Treadmills User Guide
Grounding brackets, Step 8
9. To install the hood cover, place the cover over the tab on
the hood.
10. Lower the hood cover to align the three screw holes at the
bottom of the cover. Fasten the cover using the three 1/4-
20 x 7/8-in button head screws, flat washers, and star
washers supplied. To ensure proper grounding, stack the
hardware so that the star washer is against the hood
cover.
11. Align the holes in the hood with those in the hood cover.
Install three #8 black Phillips screws and tighten
securely.
12. Use four #10 screws and external star washers to secure
the front of the hood to the configuration plate.
13. Install the two front-end caps (included) on the front ends
of the treadmill frame (figure page C-3).
14. Verify that the voltage for the power source matches the
voltage on the nameplate attached to the front of the
treadmill hood, then plug in the power cord.
Detail
Receiving and Installation C-5