FIGURE A6:
EXAMPLE OF PROPER LIFTING METHOD
NOTE: Units should be lifted by the base lifting features using
two or more lifting slings.
FIGURE A7:
EXAMPLES OF PROPER LIFTING METHOD
NOTE: Use two or more lifting slings around the pump and
the motor when the base does not have lifting features.
Make sure the slings are secure and the load is balanced
before attempting to lift.
FIGURE A8:
EXAMPLE OF IMPROPER LIFTING METHOD
NOTE: NEVER lift the unit with slings unsecured under the
base. The slings can slide, allowing the unit to tip and/or fall.
Improper lifts can result in personal injury and/or damage to
the unit.
© 2019 Viking Pump, Inc. • Cedar Falls, IA
FIGURE A9
EXAMPLE OF IMPROPER LIFTING METHOD
NOTE: NEVER lift the unit with slings connected to the
component lifting features. The lifting features are designed
for the individual component and are not rated to lift the entire
unit. Improper lifts can result in personal injury and/or damage
to the unit.
FIGURE A10-A
Use a straightedge. These
surfaces must be parallel.
Check width between these surfaces with inside calipers to
be certain the faces are equal distance apart and parallel.
FIGURE A10-B
Driver
Driven
Sheave
Sheave
A
B
When sheaves are properly aligned,
all points A, B, C, D will touch string or straightedge.
TSM 1741 | Issue B | Page 13 of 20
String
or
Straightedge
C
D