Regulations (Directives, Laws, Standards) - Vaillant ecoCOMPACT VCC4 Series Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

1 Safety
1.3.12 Risk of death from escaping flue gas
If you operate the product with an empty con-
densate siphon, flue gas may escape into the
room air.
▶ In order to operate the product, ensure that
the condensate siphon is always full.
Conditions: Permitted B23 or B23P unit
types with condensate siphon (third-party
accessory)
– Water seal level: ≥ 200 mm
1.3.13 Risk of injury due to the heavy weight
of the product
The product weighs over 50 kg.
▶ Make sure that the product is carried by at
least two people.
▶ Use suitable transport and lifting equip-
ment, in accordance with your risk assess-
ment.
▶ Use suitable personal protective equip-
ment: Gloves, safety footwear, protective
goggles, protective helmet.
1.3.14 Risk of material damage caused by
frost
▶ Do not install the product in rooms prone
to frost.
1.3.15 Risk of corrosion damage due to
unsuitable combustion and room air
Sprays, solvents, chlorinated cleaning
agents, paint, adhesives, ammonia com-
pounds, dust or similar substances may lead
to corrosion on the product and in the flue
system.
▶ Ensure that the supply of combustion air is
always free of fluorine, chlorine, sulphur,
dust, etc.
▶ Ensure that no chemical substances are
stored at the installation site.
▶ If you are installing the product in
hairdressing salons, painter's or joiner's
workshops, cleaning businesses or similar
locations, choose a separate installation
room in which the room air is technically
free of chemical substances.
6
▶ Ensure that the combustion air is not
routed through chimneys which have
previously been used with floor-standing
oil-fired boilers, or with other boilers,
which could cause soot to build up in the
chimney.
1.3.16 Risk of material damage caused by
leak detection sprays and fluids
Leak detection sprays and fluids block the
filter for the mass flow sensor on the Venturi,
thereby destroying the mass flow sensor.
▶ During repair work, do not apply any leak
detection sprays or fluids to the covering
cap on the filter for the Venturi.
1.3.17 Risk of damage to the flexible gas
pipe
The corrugated gas pipe may become dam-
aged if weight is placed on it.
▶ Do not suspend the compact thermal
module on the flexible gas pipe, for
example during maintenance work.
1.3.18 Risk of material damage caused by
using an unsuitable tool
▶ Use the correct tool.
1.4
Regulations (directives, laws,
standards)
▶ Observe the national regulations, stand-
ards, directives, ordinances and laws.
Installation and maintenance instructions ecoCOMPACT 0020181421_04

Advertisement

Table of Contents
loading