Panasonic CS-BE35TKE-1 Service Manual page 7

Hide thumbs Also See for CS-BE35TKE-1:
Table of Contents

Advertisement

Model
Pipe Diameter (Liquid / Gas)
Standard length
Length range (min – max)
I/D & O/D Height different
Additional Gas Amount
Length for Additional Gas
Inner Diameter
Drain Hose
Length
Fin Material
Fin Type
Indoor Heat
Exchanger
Row × Stage × FPI
Size (W × H × L)
Fin Material
Outdoor
Fin Type
Heat
Row × Stage × FPI
Exchanger
Size (W × H × L)
Material
Air Filter
Type
Power Supply
Power Supply Cord
Thermostat
Protection Device
Cooling
Indoor
Operation
Range
Heating
Cooling
Outdoor
Operation
Range
Heating
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C.
5.
Standby power consumption ≤ 2.0W (when switched OFF by remote control, except under self-protection control).
6.
Specifications are subjected to change without prior notice for further improvement.
7.
Maximum heating capacity shown are the values based on powerful operation.
8.
If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C DB and -8°C WB temperature with
rated voltage 230V shall be used.
9.
The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode.
10. SEER and SCOP classification is at 230V only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating
season. Other fiche data indicates in an attached sheet.
Indoor
Outdoor
mm (inch)
m (ft)
m (ft)
m (ft)
g/m (oz/ft)
m (ft)
mm
mm
mm
mm
A
Dry Bulb
Maximum °C
32
Minimum °C
16
Maximum °C
30
Minimum °C
16
Maximum °C
43
Minimum °C
5
Maximum °C
24
Minimum °C
-15
CS-BE25TKE-1
CU-BE25TKE-1
6.35 (1/4) / 9.52 (3/8)
5.0 (16.4)
3 (9.8) ~ 15 (49.2)
15.0 (49.2)
15 (0.2)
7.5 (24.6)
16.7
650
Aluminium (Pre Coat)
Slit Fin
2 × 15 × 17
610 × 315 × 25.4
Aluminium (Pre Coat)
Corrugated Fin
1 × 24 × 17
18.2 × 504 × 710.0
Polypropelene
One-touch
Indoor
Nil
Nil
Nil
Wet Bulb
23
11
26
18
-16
7
CS-BE35TKE-1
CU-BE35TKE-1
6.35 (1/4) / 9.52 (3/8)
5.0 (16.4)
3 (9.8) ~ 15 (49.2)
15.0 (49.2)
15 (0.2)
7.5 (24.6)
16.7
650
Aluminium (Pre Coat)
Slit Fin
2 × 15 × 17
610 × 315 × 25.4
Aluminium (Pre Coat)
Corrugated Fin
1 × 24:12 × 17
36.4 × 504:252 × 713:684
Polypropelene
One-touch
Indoor
Nil
Nil
Nil
Dry Bulb
Wet Bulb
32
23
16
11
30
16
43
26
5
24
18
-15
-16

Hide quick links: