Indoor Unit - Panasonic CS-BE35TKE-1 Service Manual

Hide thumbs Also See for CS-BE35TKE-1:
Table of Contents

Advertisement

11.2 Indoor Unit

11.2.1 How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from vibration.
Measuring Tape
FE25***, BE25***, DE25***,
FE35***, BE35***, DE35***
Measuring Tape
FE50***
The center of installation plate should be at more than 1 at right and left of the wall.
The distance from installation plate edge to ceiling should more than 2.
From installation plate center to unit's left side is 3.
From installation plate center to unit's right side is 4.
: For left side piping, piping connection for liquid should be about 5 from this line.
B
: For left side piping, piping connection for gas should be about 6 from this line.
1
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
o
a level gauge.
2
Drill the piping plate hole with ø70 mm hole-core drill.
Line according to the left and right side of the installation plate. The meeting point of the extended line is
o
the center of the hole. Another method is by putting measuring tape at position as shown in the diagram
above. The hole center is obtained by measuring the distance namely 128 mm for left and right hole
respectively.
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
o
side.
Wall
More than
228 mm
PIPE
HOLE
CENTER
128mmTO
PIPEHOLE
CENTER
128 mm
Model
1
480 mm
Wall
More than
241.5 mm
PIPE
HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
128 mm
Model
1
490 mm
Ceiling
1
More than
2 screw
2
3
Installation
B
plate 1
For best strength of
C
INDOOR unit installation,
it is highly recommended
to locate " " at 5 position
as shown.
Dimension
2
3
90 mm
425 mm
Ceiling
1
More than
2 screw
2
3
Installation
B
plate 1
For best strength of
C
INDOOR unit installation,
it is highly recommended
to locate " " at 5 position
as shown.
Dimension
2
3
85 mm
439 mm
25
1
More than
Indoor unit
4
228 mm
PIPE
HOLE
CENTER
A
128mmTO
PIPE HOLE
CENTER
128 mm
4
5
6
425 mm
43 mm
95 mm
1
More than
Indoor unit
4
241.5 mm
PIPE
HOLE
CENTER
A
128mm TO
PIPE HOLE
CENTER
128 mm
4
5
6
432 mm
43 mm
95 mm
Wall
Wall

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents