11.3.10 Check the Drainage
Open front panel and remove air filters. (Drainage checking can be carried out without removing the front grille.)
Pour a glass of water into the drain tray-styrofoam.
Ensure that water flows out from drain hose of the indoor unit.
11.3.11 Evaluation of the Performance
1
Operate the unit at cooling/heating operation mode for fifteen minutes or more.
2
Measure the temperature of the intake and discharge air.
3
Ensure the difference between the intake temperature and the discharge is more than 8°C during Cooling
operation or more than 14°C during Heating operation.
11.3.12 Installation of Air Purifying Filter
1
Open the front panel.
2
Remove the air filters.
3
Put the Air purifying filter into place as shown in illustration at right.
Air purifying filter 8
Air filter
Applicable model FE25***, FE35***
Drain tray-styrofoam
Discharge air
Air filter
Applicable model FE50***
34
Air purifying filter 8

Hide quick links: