Operating & Maintenance Instructions
The charger may become hot during charging. Do not touch the charger when it is charging.
To maintain safe operations, the unit automatically reduces its output power if the temperature rises above
set thresholds, or if the AC input voltage is too low. The charger also reduces output power if it detects the
battery pack is damaged.
If power is interrupted, and then returns, the charger starts and continues to operate without hazard to the
user, or damage to the batteries.
Unplug the charger from AC when cleaning, moving, or conducting any maintenance or repair on the
vehicle. No user serviceable parts are inside the charger. Do not remove the charger or the cover due to
the risk of electrical shock.
Do not expose the charger to oil, dirt, mud, or direct heavy water spray when cleaning the vehicle or machine.
The enclosure on these chargers meets IP56, making it protected from dust ingress and powerful water
jets. The AC receptacle requires an external AC cord which is not protected against dust or water. Protect
this AC connection if the charger is used in wet or dusty environments. Inspect it regularly for
contamination. If the charger and/or cord are in a damp location, use a Class A GFCI AC outlet.
If the detachable AC input power cord or DC output cord is damaged, do not use the charger until they are
replaced by a qualified service technical with cord sets appropriate to your region and application.
To charge your vehicle, use a 3-wire extension cord less than 30m (100') at 10 AWG or 7.5m (25') at 16
AWG, per UL guidelines.
AC Receptacle Indicators
LED
Off
Slow Green Breathing
Fast Green Breathing
Solid Green
Rapid Amber Flash
Solid Red
Identifying Charger Serial Number
The serial number is printed on the front of the charger. Use this number when requesting technical support.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC/ICES Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
Delta-Q Technologies Corp.
3755 Willingdon Ave.
Burnaby, B.C. V5G 3H3 CANADA
Phone: +1.604.327.8244
Indication
No AC Power. Check for AC cord
damage; plug into AC power outlet;
ensure AC outlet has power.
More than 80% state of charge.
Less than 80% state of charge.
Charge Complete
Error. Unplug and plug the charger in
again. If the error remains, contact a
qualified service technician.
Fault. Unplug and plug the charger in
again. If the fault remains, contact a
qualified service technician.
Email: support@delta-q.com
Web: www.delta-q.com
User Documentation: www.delta-q.com/resources