Summary of Contents for urmet domus Digivoice 1038/16

  • Page 1 Guide to replacing the Digivoice 1038/16 Call Module Retrieving programming information from the existing 1038/16 Page 1 Page 4 Swapping the existing 1038/16 Page 5 Programming the new 1038/16 Page 7 1038/16 voltages...
  • Page 2 Retrieving programming information from the existing 1038/16 Before replacing the 1038/16, if possible retrieve the programming information from the existing unit as follows - Press the Programming button on the rear of the 1038/16 call module You will see Use the buttons to select then press You will see this screen -...
  • Page 3 Important note – If the 1038/16 which is to be replaced is part of a complex installation with main and secondary call modules AND it is not possible to retrieve the existing programming information then you must contact Urmet Technical Support. An example of a complex installation with main and secondary call modules is as follows –...
  • Page 4 You will see – Use the buttons to select then press You will see – The existing code used to open the door will appear here instead of 00000000. Make a note of this code Press and hold for four seconds to exit the programming mode.
  • Page 5 Swapping the existing 1038/16 Before changing the 1038/16 check that the K-Steel entry panel has been correctly installed in the first instance. Specifically – Make sure that the internal module guard is fitted in the top of the back box - This guard prevents condensation from dripping into the 1038/16 and warranty is void if it is not fitted.
  • Page 6 Programming the new 1038/16 When the 1038/16 is first powered the display will be in Italian. Press 00 9998 . You will then see – Use the buttons to select then press You will then see – Use the buttons to select then press Use the buttons to select...
  • Page 7 To choose the default value press You will see – <FREE> means that the user can open the door without being called. <SEC> You will see – means the user must be called before they can open the door. <SEC> is the normal choice.
  • Page 8 You will see – Change as required and press To finish programming press and hold the button until you see Note – there is no need to swap any IC’s from the old 1038/16 unless there are many names in the directory. All of the apartment numbering information is held in the 4-user decoders and not in the 1038/16 For detailed programming information see the documentation provided with the 1038/16 1038/16 voltages...